ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2020
UV light-based decontamination: an effective and fast way for disinfection of endoscopes in otorhinolaryngology?
Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- A multicenter study comparing the bacterial reduction on flexible endoscopes without a working channel between UV-C light disinfection versus standard endoscope Washer Disinfection: a randomized controlled trial.Antimicrobial resistance and infection control · 2024Trial
- Biofilm-Mediated Persistence of Salmonella in Poultry Processing: A Comprehensive Review of Isolate Heterogeneity, Stress Adaptation, and Antimicrobial Resistance.Comprehensive reviews in food science and food safety · 2026Review
- UV-C LED Disinfection of Flexible Rhinolaryngoscopes: Microbiological, Economic, Environmental, and Legislative Evaluation.Laryngoscope investigative otolaryngology · 2026Article
- Environmental Impact of a Novel UV-C Disinfection Machine for Non-Channel Flexible Laryngoscopes.Laryngoscope investigative otolaryngology · 2026Article
- Virucidal efficacy of a UV-C disinfection system for semi-critical medical devices according to EN 14476.GMS hygiene and infection control · 2026Article
- Is UV-C light disinfection suitable as a disinfection method for medical devices: a scoping review.Antimicrobial resistance and infection control · 2025Article
- Article
- Cost minimization analysis of nasopharyngoscope reprocessing in community practice.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2023Article
- UV-C Light-Based Surface Disinfection: Analysis of Its Virucidal Efficacy Using a Bacteriophage Model.International journal of environmental research and public health · 2022Article
- Analysis of bacterial contamination and the effectiveness of UV light-based reprocessing of everyday medical devices.PloS one · 2022Article
- UV light-based reprocessing of flexible endoscopes without working channel in Oto-Rhino-Laryngology: an effective method?European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundReprocessing of endoscopes becomes increasingly complex, due to rising demands of hygiene. Established methods are often expensive/time-consuming. Recent studies suggest beneficial aspects of disinfection by UV light. In this study we analyzed the efficiency of UV light disinfection of rigid otorhinolaryngological endoscopes. MATERIALS AND
methodsAfter mechanical pre-cleaning, the endoscopes were decontaminated for 25 s in the D25 using Impelux™ UV C light technology (UV Smart B.V., Delft, The Netherlands). First, the surface contact samples were taken from 50 used endoscopes to evaluate the bacterial load. Additionally, surface contact samples were taken from further 50 used endoscopes after reprocessing with the D25. Another 50 endoscopes were tested on protein residuals. Furthermore, the absolute effectiveness of the D25 was tested on 50 test bodies (RAMS) with a standardized contamination of 10
resultsThe used endoscopes showed a high bacterial contamination with an average value of 66.908 (± 239.215) CFU. After reprocessing, only a minimal contamination on 10% (n = 5) of the endoscopes with a mean value of 0.12 CFU (± 0.39) was found, resulting in a log-5 reduction in a clinical environment. The documented bacteria were components of the normal skin flora. All tested endoscopes were practically protein-free (< 1 μg). Furthermore, the average absolute germ reduction of the D25 was about 10
conclusionThe D25 UV light system seems to be an effective device for the reprocessing of rigid ORL endoscopes, and therefore, might be suitable for the usage in clinical practice on site.
Indexed as