Evidence map›Paper›PMID 32356885›Full record

SynthesisJAMA network open2020

Adherence to the Standards for Reporting of Diagnostic Accuracy (STARD) 2015 Guidelines in Acute Point-of-Care Ultrasound Research.

Ross Prager, Joshua Bowdridge, Hashim Kareemi, Chris Wright, Trevor A McGrath, Matthew D F McInnes

Abstract readSystematic Review
In one paragraph

Synthesis in JAMA network open, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. The role of repeated extended FAST in patients with stable blunt thoracoabdominal trauma.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2023
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ross PragerDepartment of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Joshua BowdridgeDepartment of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Hashim KareemiDepartment of Emergency Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Chris WrightDepartment of Radiology, University of Calgary, Calgary, Alberta, Canada.
Trevor A McGrathDepartment of Radiology, University of Ottawa, Ottawa, Ontario, Canada.
Matthew D F McInnesDepartment of Radiology, University of Ottawa, Ottawa, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Incomplete reporting of diagnostic accuracy research impairs assessment of risk of bias and limits generalizability. Point-of-care ultrasound has become an important diagnostic tool for acute care physicians, but studies assessing its use are of varying methodological quality. Objective: To assess adherence to the Standards for Reporting of Diagnostic Accuracy (STARD) 2015 guidelines in the literature on acute care point-of-care ultrasound. Evidence Review: MEDLINE was searched to identify diagnostic accuracy studies assessing point-of-care ultrasound published in critical care, emergency medicine, or anesthesia journals from 2016 to 2019. Studies were evaluated for adherence to the STARD 2015 guidelines, with the following variables analyzed: journal, country, STARD citation, STARD-adopting journal, impact factor, patient population, use of supplemental material, and body region. Data analysis was performed in November 2019. Findings: Seventy-four studies were included in this systematic review for assessment. Overall adherence to STARD was moderate, with 66% (mean [SD], 19.7 [2.9] of 30 items) of STARD items reported. Items pertaining to imaging specifications, patient population, and readers of the index test were frequently reported (>66% of studies). Items pertaining to blinding of readers to clinical data and to the index or reference standard, analysis of heterogeneity, indeterminate and missing data, and time intervals between index and reference test were either moderately (33%-66%) or infrequently (<33%) reported. Studies in STARD-adopting journals (mean [SD], 20.5 [2.9] items in adopting journals vs 18.6 [2.3] items in nonadopting journals; P = .002) and studies citing STARD (mean [SD], 21.3 [0.9] items in citing studies vs 19.5 [2.9] items in nonciting studies; P = .01) reported more items. Variation by country and journal of publication were identified. No differences in STARD adherence were identified by body region imaged (mean [SD], abdominal, 20.0 [2.5] items; head and neck, 17.8 [1.6] items; musculoskeletal, 19.2 [3.1] items; thoracic, 20.2 [2.8] items; and other or procedural, 19.8 [2.7] items; P = .29), study design (mean [SD], prospective, 19.7 [2.9] items; retrospective, 19.7 [1.8] items; P > .99), patient population (mean [SD], pediatric, 20.0 [3.1] items; adult, 20.2 [2.7] items; mixed, 17.9 [1.9] items; P = .09), use of supplementary materials (mean [SD], yes, 19.2 [3.0] items; no, 19.7 [2.8] items; P = .91), or journal impact factor (mean [SD], higher impact factor, 20.3 [3.1] items; lower impact factor, 19.1 [2.4] items; P = .08). Conclusions and Relevance: Overall, the literature on acute care point-of-care ultrasound showed moderate adherence to the STARD 2015 guidelines, with more complete reporting found in studies citing STARD and those published in STARD-adopting journals. This study has established a current baseline for reporting; however, future studies are required to understand barriers to complete reporting and to develop strategies to mitigate them.

Indexed as

Guideline AdherencePractice Guidelines as TopicDiagnostic Tests, RoutineHumansPoint-of-Care SystemsUltrasonography

Identifiers

PMID32356885
PMCPMC7195624

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.