Evidence map›Paper›PMID 32347527›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2021

Standard SPECT myocardial perfusion estimation from half-time acquisitions using deep convolutional residual neural networks.

Isaac Shiri, Kiarash AmirMozafari Sabet, Hossein Arabi, Mozhgan Pourkeshavarz, Behnoosh Teimourian, Mohammad Reza Ay, Habib Zaidi

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
6.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 85 citations in OpenAlex.

  1. Accelerating imaging: deep learning for enhancedJapanese journal of radiology · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Deep learning to automate SPECT MPI myocardial reorientation.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  17. Article
  18. Article
  19. Deep learning-based denoising in projection-domain and reconstruction-domain for low-dose myocardial perfusion SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  20. Acquisition time reduction in pediatricJournal of applied clinical medical physics · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 4 countries.

Isaac ShiriDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland.
Kiarash AmirMozafari SabetSchool of Electrical Engineering, Sharif University of Technology, Tehran, Iran.
Hossein ArabiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland.
Mozhgan PourkeshavarzRajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran.
Behnoosh TeimourianResearch Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran.
Mohammad Reza AyResearch Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran.
Habib ZaidiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland. habib.zaidi@hcuge.ch.
Tehran University of Medical Sciences · IRUniversity Hospital of Geneva · CHShaheed Rajaei Cardiovascular Medical and Research Center · IRSharif University of Technology · IRUniversity of Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe purpose of this work was to assess the feasibility of acquisition time reduction in MPI-SPECT imaging using deep leering techniques through two main approaches, namely reduction of the acquisition time per projection and reduction of the number of angular projections.

methodsSPECT imaging was performed using a fixed 90° angle dedicated dual-head cardiac SPECT camera. This study included a prospective cohort of 363 patients with various clinical indications (normal, ischemia, and infarct) referred for MPI-SPECT. For each patient, 32 projections for 20 seconds per projection were acquired using a step and shoot protocol from the right anterior oblique to the left posterior oblique view. SPECT projection data were reconstructed using the OSEM algorithm (6 iterations, 4 subsets, Butterworth post-reconstruction filter). For each patient, four different datasets were generated, namely full time (20 seconds) projections (FT), half-time (10 seconds) acquisition per projection (HT), 32 full projections (FP), and 16 half projections (HP). The image-to-image transformation via the residual network was implemented to predict FT from HT and predict FP from HP images in the projection domain. Qualitative and quantitative evaluations of the proposed framework was performed using a tenfold cross validation scheme using the root mean square error (RMSE), absolute relative error (ARE), structural similarity index, peak signal-to-noise ratio (PSNR) metrics, and clinical quantitative parameters.

resultsThe results demonstrated that the predicted FT had better image quality than the predicted FP images. Among the generated images, predicted FT images resulted in the lowest error metrics (RMSE = 6.8 ± 2.7, ARE = 3.1 ± 1.1%) and highest similarity index and signal-to-noise ratio (SSIM = 0.97 ± 1.1, PSNR = 36.0 ± 1.4). The highest error metrics (RMSE = 32.8 ± 12.8, ARE = 16.2 ± 4.9%) and the lowest similarity and signal-to-noise ratio (SSIM = 0.93 ± 2.6, PSNR = 31.7 ± 2.9) were observed for HT images. The RMSE decreased significantly (P value < .05) for predicted FT (8.0 ± 3.6) relative to predicted FP (6.8 ± 2.7).

conclusionReducing the acquisition time per projection significantly increased the error metrics. The deep neural network effectively recovers image quality and reduces bias in quantification metrics. Further research should be undertaken to explore the impact of time reduction in gated MPI-SPECT.

Indexed as

Coronary CirculationNeural Networks, ComputerCardiac Imaging TechniquesFeasibility StudiesHumansMyocardial Perfusion ImagingProspective StudiesTime FactorsTomography, Emission-Computed, Single-Photondeep learningmyocardial perfusion imagingshort acquisitionSPECT

Identifiers

PMID32347527
OpenAlexW3019885855

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.