Effective dose to patient measurements for flat-detector computed tomography protocols in acute stroke care.

Alex Brehm, Georg Stamm, Matthias Lüpke, Christian Riedel, Bram Stieltjes, Marios-Nikos Psychogios

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Alex BrehmDepartment of Neuroradiology, Clinic of Radiology & Nuclear Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland. Alex.brehm@usb.ch.
Georg StammDepartment of Radiology, University Medical Center Goettingen, Goettingen, Germany.
Matthias LüpkeDepartment of Radiology and Medical Physics, University of Veterinary Medicine Hannover, Hannover, Germany.
Christian RiedelDepartment of Neuroradiology, University Medical Center Goettingen, Goettingen, Germany.
Bram StieltjesDepartment of Research, Clinic of Radiology & Nuclear Medicine, University Hospital Basel, Basel, Switzerland.
Marios-Nikos PsychogiosDepartment of Neuroradiology, Clinic of Radiology & Nuclear Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
University Hospital of Basel · CHMedizinische Hochschule Hannover · DEUniversity of Göttingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe aim was to measure the effective dose of flat-detector CT (FDCT) whole-brain imaging, biphasic FDCT angiography (FDCT-A), and FDCT perfusion (FDCT-P) protocols and compare it to previously reported effective dose values of multidetector CT (MDCT) applications. MATERIALS: We measured effective dose according to the IRCP 103 using an anthropomorphic phantom equipped with thermoluminescent dosimeters (TLDs). Placement was according to anatomical positions of each organ. In total, 60 TLDs (≥ 4 TLDs/organ) were placed into and onto the phantom to account for all relevant organs. Organs within the primary beam were covered with more TLDs. Additionally, we measured dose to the eye lens with two TLDs per eye. Protocols which we routinely use in clinical practice were measured on a biplane angiography system.

resultsThe effective dose of the 20-s protocol/7-s protocol for whole-brain imaging was 2.6 mSv/2.4 mSv. The radiation dose to the eye lens was 24/23 mGy. For the biphasic high-/low-dose FDCT-A protocol, the effective dose was 8.9/2.8 mSv respectively. The eye lens dose was 60/14 mGy. The contribution of bolus tracking to the effective dose was 0.66 mSv (assuming average duration of 14 s). The multisweep FDCT-P protocol had an effective dose of 5.9 mSv and an eye lens dose of 46 mGy.

conclusionExcept for the high-dose biphasic FDCT-A protocol, FDCT applications used in neuroradiology have effective doses, which do not deviate more than 1 mSv from previously reported values for MDCT applications. However, the effective dose to the eye lens in commonly used stroke paradigms exceeds the recommended annual dose twofold. KEY POINTS: • Flat-detector computed tomography (FDCT) can be used for acute and periinterventional imaging of acute stroke patients and in neurointerventions. • Except for the high-dose FDCT angiography protocol, the effective doses do not deviate more than 1 mSv from previously reported values for multidetector CT applications. • Strategies to decrease the effective lens dose especially in younger patients should be evaluated in the future.

Indexed as

Radiation DosageBrainCerebral AngiographyComputed Tomography AngiographyHumansMultidetector Computed TomographyPerfusion ImagingPhantoms, ImagingStrokeThermoluminescent DosimetryTomography, X-Ray ComputedAngiographyCone-beam computed tomographyPerfusionRadiation dosageStroke

Identifiers

PMID32346793
OpenAlexW3020229439

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.