Evidence map›Paper›PMID 32346327›Full record

ArticleSaudi journal of biological sciences2020

The application of 3D printing patient specific instrumentation model in total knee arthroplasty.

Fengxin Zhou, Feng Xue, Shuquan Zhang

Abstract read
In one paragraph

Article in Saudi journal of biological sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Article
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Fengxin ZhouDepartment of Orthopaedics, Tianjin Nankai Hospital, Tianjin 300192, China.
Feng XueDepartment of Orthopaedics, Tianjin Nankai Hospital, Tianjin 300192, China.
Shuquan ZhangDepartment of Orthopaedics, Tianjin Nankai Hospital, Tianjin 300192, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The application of 3D printing patient specific instrumentation model in total knee arthroplasty was explored to improve the operative accuracy and safety of artificial total knee arthroplasty. In this study, a total of 52 patients who need knee replacement were selected as the study objects, and 52 patients were divided into experimental group and control group. First, the femoral mechanical-anatomical angle (FMAA), lateral femoral angle (LFA), hip-knee-ankle angle (HKA), femorotibial angle (FTA) of research objects in both groups were measured. Then, the blood loss during the operations, drainage volume after operations, total blood loss, hidden blood loss, and hemoglobin decrease of the experiment group and the control group were measured and calculated. Finally, the postoperative outcomes of patients who underwent total knee arthroplasty were evaluated. The results showed that before the operations, in the PSI group, the femoral mechanical-anatomical angle (FMAA) was (6.9 ± 2.4)°, the lateral femoral angle (LFA) was (82.4 ± 1.6)°, the hip-knee-ankle angle (HKA) was (166.4 ± 1.4)°, and the femorotibial angle (FTA) was (179.5 ± 7.3)°. In the CON group, the FMAA was (5.8 ± 2.4)°, the LFA was (81.3 ± 2.1)°, the HKA was (169.5 ± 1.9)°, and the FTA was (185.4 ± 5.4)°. The differences in these data between the two groups were not statistically significant (P > 0.05). After the operations, in the PSI group, the total blood loss, the hidden blood loss, and the hemoglobin (Hb) decrease were respectively (420.2 ± 210.5), (240.5 ± 234.5), and (1.7 ± 0.9); in the CON group, the total blood loss, the hidden blood loss, and the Hb decrease were respectively (782.1 ± 340.4), (450.9 ± 352.6), and (2.9 ± 1.0). These data of both groups were statistically significant (P < 0.05). Therefore, it can be seen that the 3D printing patient specific instrumentation model can effectively simulate the lower limb coronal force line and was highly consistent of the preoperative software simulation plan. In addition, the random interviews of patients who underwent total knee arthroplasty showed that the knees of patients had recovered well. The application of 3D printing patient specific instrumentation model in artificial total knee arthroplasty can effectively improve the operative accuracy and safety, and the clinical therapeutic effects were significant.

Indexed as

3D printingHip-knee-ankle angleLateral femoral anglePatient specific instrumentationTotal knee arthroplasty

Identifiers

PMID32346327
PMCPMC7182983

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.