Evidence map›Paper›PMID 32341418›Full record

ArticleScientific reports2020

Assessing TEG6S reliability between devices and across multiple time points: A prospective thromboelastography validation study.

Patryck Lloyd-Donald, Leonid Churilov, Brandon Cheong, Rinaldo Bellomo, Peter R McCall, Johan Mårtensson, Neil Glassford, Laurence Weinberg

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Utility of point of care viscoelastic haemostatic assays for trauma patients in the emergency department.Scandinavian journal of trauma, resuscitation and emergency medicine · 2025
    Observational
  2. Article
  3. Article
  4. Review
  5. Viscoelastic testing: an illustrated review of technology and clinical applications.Research and practice in thrombosis and haemostasis · 2023
    Review
  6. Article
  7. Comparison of Thromboelastography Devices TEGThe journal of extra-corporeal technology · 2022
    Article
  8. Review
  9. Review
  10. Clinical Application of Thromboelastography in Acute Ischemic Stroke.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Patryck Lloyd-DonaldDepartment of Anaesthesia, Austin Hospital, 145 Studley Rd, Heidelberg, 3084, Victoria, Australia.
Leonid ChurilovDepartment of Medicine, Austin Health, Melbourne Medical School, University of Melbourne, 245 Burgundy St, Heidelberg, 3084, Victoria, Australia.
Brandon CheongDepartment of Anaesthesia, Austin Hospital, 145 Studley Rd, Heidelberg, 3084, Victoria, Australia.
Rinaldo BellomoDepartment of Intensive Care, Austin Hospital, 145 Studley Rd, Heidelberg, 3084, Victoria, Australia.
Peter R McCallDepartment of Anaesthesia, Austin Hospital, 145 Studley Rd, Heidelberg, 3084, Victoria, Australia.
Johan MårtenssonDepartment of Perioperative Medicine and Intensive Care Medicine, Karolinska University Hospital, Solna, and Department of Physiology and Pharmacology, Karolinska Institutet, SE-171 77, Stockholm, Sweden.
Neil GlassfordDepartment of Intensive Care, Austin Hospital, 145 Studley Rd, Heidelberg, 3084, Victoria, Australia.
Laurence WeinbergDepartment of Anaesthesia, Austin Hospital, 145 Studley Rd, Heidelberg, 3084, Victoria, Australia. laurence.weinberg@austin.org.au.ORCID http://orcid.org/0000-0001-7403-7680

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The TEG6S is a novel haemostasis analyser utilising resonance technology. It offers potentially greater coagulation information and ease of use, however has not been independently validated in a clinical setting. We aimed to determine if the TEG6S is reliable between devices and across time points. We performed a prospective observational study with ethical approval. For interdevice reliability, we performed simultaneous analysis on two TEG6S devices on 25 adult ICU patients. For time point reliability, we performed repeated sampling across five different time points on 15 adult participants. Blood was collected with informed consent, or as standard care, before four-channel citrated kaolin analysis. We observed almost perfect interdevice reliability across all TEG parameters. The Lin's concordance correlation coefficients (95% CI, major axis regression slope, intercept) were R-time: 0.96 (0.92-0.99, 0.88, 0.57); K-time: 0.93 (0.87-0.98, 1.07, 0.00); Alpha Angle: 0.87 (0.78-0.96, 1.20, -14.10); Maximum Amplitude: 0.99 (0.98-0.99, 1.02, -1.38); Clot Lysis: 0.89 (0.82-0.97, 1.20, 0.07). Additionally, we observed moderate-to-high reliability across time points. Demonstrating almost perfect agreement across different devices and moderate-to-high reliability across multiple time points, suggests the TEG6S platform can be used with haemostatic accuracy and generalisability. This has potentially significant implications for clinical practice and multi-site research programs.

Indexed as

AdultAgedAged, 80 and overBlood CoagulationFemaleHemostasisHumansKaolinMaleMiddle AgedProspective StudiesThrombelastographyYoung AdultKaolin

Identifiers

PMID32341418
PMCPMC7184600

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.