Assessing TEG6S reliability between devices and across multiple time points: A prospective thromboelastography validation study.
Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Utility of point of care viscoelastic haemostatic assays for trauma patients in the emergency department.Scandinavian journal of trauma, resuscitation and emergency medicine · 2025Observational
- Discrepancy Between Conventional Coagulation Tests and Thromboelastography During the Early Postoperative Phase of Liver Resection in Neoplastic Patients: A Prospective Study Using the New-Generation TEGJournal of clinical medicine · 2025Article
- TEG® 6s coagulation testing with a novel heparin neutralization cartridge: Technical validation and determination of normal reference ranges.American journal of clinical pathology · 2025Article
- Modified Thromboelastography for Peri-interventional Assessment of Platelet Function in Cardiology Patients: A Narrative Review.Seminars in thrombosis and hemostasis · 2023Review
- Viscoelastic testing: an illustrated review of technology and clinical applications.Research and practice in thrombosis and haemostasis · 2023Review
- Operability of a Resonance-Based Viscoelastic Haemostatic Analyzer in the High-Vibration Environment of Air Medical Transport.Journal of clinical medicine · 2022Article
- Comparison of Thromboelastography Devices TEGThe journal of extra-corporeal technology · 2022Article
- Thrombocytopenia and Hemostatic Changes in Acute and Chronic Liver Disease: Pathophysiology, Clinical and Laboratory Features, and Management.Journal of clinical medicine · 2021Review
- Platelet Mechanobiology Inspired Microdevices: From Hematological Function Tests to Disease and Drug Screening.Frontiers in pharmacology · 2021Review
- Clinical Application of Thromboelastography in Acute Ischemic Stroke.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/HemostasisReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The TEG6S is a novel haemostasis analyser utilising resonance technology. It offers potentially greater coagulation information and ease of use, however has not been independently validated in a clinical setting. We aimed to determine if the TEG6S is reliable between devices and across time points. We performed a prospective observational study with ethical approval. For interdevice reliability, we performed simultaneous analysis on two TEG6S devices on 25 adult ICU patients. For time point reliability, we performed repeated sampling across five different time points on 15 adult participants. Blood was collected with informed consent, or as standard care, before four-channel citrated kaolin analysis. We observed almost perfect interdevice reliability across all TEG parameters. The Lin's concordance correlation coefficients (95% CI, major axis regression slope, intercept) were R-time: 0.96 (0.92-0.99, 0.88, 0.57); K-time: 0.93 (0.87-0.98, 1.07, 0.00); Alpha Angle: 0.87 (0.78-0.96, 1.20, -14.10); Maximum Amplitude: 0.99 (0.98-0.99, 1.02, -1.38); Clot Lysis: 0.89 (0.82-0.97, 1.20, 0.07). Additionally, we observed moderate-to-high reliability across time points. Demonstrating almost perfect agreement across different devices and moderate-to-high reliability across multiple time points, suggests the TEG6S platform can be used with haemostatic accuracy and generalisability. This has potentially significant implications for clinical practice and multi-site research programs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.