Evidence map›Paper›PMID 32341408›Full record

ArticleScientific reports2020

Separation and degradation detection of nanogram-per-litre concentrations of radiolabelled steroid hormones using combined liquid chromatography and flow scintillation analysis.

Roman Lyubimenko, Bryce S Richards, Andrey Turshatov, Andrea I Schäfer

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Roman LyubimenkoInstitute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
Bryce S RichardsInstitute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
Andrey TurshatovInstitute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
Andrea I SchäferInstitute for Advanced Membrane Technology (IAMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany. Andrea.Iris.Schaefer@kit.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detection of micropollutants such as steroid hormones occurring in the aquatic environment at concentrations between ng/L and µg/L remains a major challenge, in particular when treatment efficiency is to be evaluated. Steroid hormones are typically analysed using mass-spectrometry methods, requiring pre-concentration and/or derivatisation procedures to achieve required detection limits. Free of sample preparation steps, the use of radiolabelled contaminants with liquid scintillation counting is limited to single-compound systems and require a separation of hormone mixtures before detection. In this work, a method was developed coupling ultra-high-pressure liquid chromatography (UHPLC) with flow scintillation analysis (FSA) for separation and detection of radiolabelled estrone, 17ß-estradiol, testosterone and progesterone. Adjustment of the flow rate of scintillation liquid and UHPLC mobile phase, gradient time, column temperature, and injection volume allowed the separation of steroid hormones and degradation products. The limit-of-detection (LOD = 1.5-2.4 ng/L) and limit-of-quantification (LOQ = 3.4-4.3 ng/L) for steroid hormones were comparable with the current state-of-the-art technique (LC-MS/MS) for non-derivatised compounds. Although the method cannot be applied to real water samples (unless spiked with radiotracers), it serves as a useful tool for the development of water treatment technologies at laboratory scale as demonstrated via: i) adsorption on polymer-based spherical activated carbon, ii) retention in nanofiltration, iii) photodegradation using a photocatalytic membrane.

Identifiers

PMID32341408
PMCPMC7184612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.