ArticleIEEE transactions on medical imaging2020
Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.
Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 14 citations in OpenAlex.
- Moiré fringes of photon counting grating interferometer with single-focal-spot and flat-panel X-ray sources.Medical physics · 2026Article
- Edge-illumination spectral phase-contrast tomography.Physics in medicine and biology · 2024Article
- Article
- PEPI Lab: a flexible compact multi-modal setup for X-ray phase-contrast and spectral imaging.Scientific reports · 2023Article
- Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography.European journal of nuclear medicine and molecular imaging · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
When more than two elemental materials are present in a given object, material quantification may not be robust and accurate when the routine two-material decomposition scheme in current dual energy CT imaging is employed. In this work, we present an innovative scheme to accomplish accurate three-material decomposition with measurements from a dual energy differential phase contrast CT (DE-DPC-CT) acquisition. A DE-DPC-CT system was constructed using a grating interferometer and a photon counting CT imaging system with two energy bins. The DE-DPC-CT system can simultaneously measure both the imaginary and the real part of the complex refractive index to enable a three-material decomposition. Physical phantom with 21 material inserts were constructed and measured using DE-DPC-CT system. Results demonstrated excellent accuracy in elemental material quantification. For example, relative root-mean-square errors of 4.5% for calcium and 5.2% for iodine were achieved using the proposed three-material decomposition scheme. Biological tissues with iodine inserts were used to demonstrate the potential utility of the proposed spectral CT imaging method. Experimental results showed that the proposed method correctly differentiates the bony structure, iodine, and the soft tissue in the biological specimen samples. A triple spectra CT scan was also performed to benchmark the performance of the DE-DPC-CT scan. Results demonstrated that the material decomposition from the DE-DPC-CT has a much lower quantification noise than that from the triple spectra CT scan.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.