Evidence map›Paper›PMID 32337841›Full record

ArticleJournal of applied clinical medical physics2020

Dosimetric assessment of patient-specific breath-hold reproducibility on liver motion for SBRT planning.

Lan Lu, Zi Ouyang, Sara Lin, Anthony Mastroianni, Kevin L Stephans, Ping Xia

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Impact on liver position under breath-hold by computed tomography contrast agents in stereotactic body radiotherapy of liver cancer.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2021
    Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Lan LuDepartment of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH, USA.
Zi OuyangDepartment of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH, USA.
Sara LinDepartment of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH, USA.
Anthony MastroianniDepartment of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH, USA.
Kevin L StephansDepartment of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH, USA.
Ping XiaDepartment of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic, Cleveland, OH, USA.
Cleveland Clinic · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the impact of breath-hold reproducibility on liver motion using a respiratory motion management device.

methodsForty-four patients with hepatic tumors, treated with SBRT with breath-hold, were randomly selected for this study. All patients underwent three consecutive computed tomography (CT) scans using active breath-hold coordinator (ABC) with three repeated single breath-hold during simulation. The three CT scans were labeled as ABC1-CT, ABC2-CT, and ABC3-CT. Displacements of centroids of the entire livers among the three ABC-CTs were measured as a surrogate for intrafractional motion. For each patient, two different treatment plans were prepared: (a) a clinical plan using a 5-mm expansion of an ITV that encompassed all three GTVs from each of the three ABC-CTs, and (b) a research plan using a 5-mm expansion of the GTV from only ABC1-CT to create PTV. The clinical plan acceptance criteria were that 95% of the PTV and 99% of the GTV received 100% of the prescription dose. Dosimetric endpoints were analyzed and compared for the two plans.

resultsAll shifts in the medial-lateral direction (range: -3.9 to 2.0 mm) were within 5 mm while 7% of shifts in the anterior-posterior direction (range: -10.5 to 16.7 mm) and 11% of shifts in the superior-inferior direction (range: -17.0 to 8.7 mm) exceeded 5 mm. Six patients (14%) had an intrafraction motion greater than 5 mm in any direction. For these six patients, if a plan was created based on a PTV from a single CT (ex. ABC1-CT), 5 of 12 GTVs captured from other ABC-CTs would fail to meet the clinical acceptance criteria due to poor breath-hold reproducibility.

conclusionsNon-negligible intrafractional motion occurs in patients with poor breath-hold reproducibility. To identify this subgroup of patients, acquiring three CTs with active breath-hold during simulation is a feasible practical method.

Indexed as

Lung NeoplasmsRadiosurgeryHumansLiverRadiotherapy Planning, Computer-AssistedReproducibility of ResultsRespirationactive breathing controlintrafractional motionliver SBRTtarget coveragetreatment plan

Identifiers

PMID32337841
PMCPMC7386188
OpenAlexW3018727104

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.