Evidence map›Paper›PMID 32336050›Full record

ArticleClinical endoscopy2020

Three-Dimensional Flexible Endoscopy Can Facilitate Efficient and Reliable Endoscopic Hand Suturing: An ex-vivo Study.

Jun Omori, Osamu Goto, Kazutoshi Higuchi, Takamitsu Umeda, Naohiko Akimoto, Masahiro Suzuki, Kumiko Kirita, Eriko Koizumi, Hiroto Noda, Teppei Akimoto and 2 more

Open access · goldAbstract read
In one paragraph

Article in Clinical endoscopy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Endoscopic hand suturing after advanced endoscopic procedures: early outcomes of 31 cases in the upper and lower gastrointestinal tract (with video).Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Jun OmoriDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Osamu GotoDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Kazutoshi HiguchiDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Takamitsu UmedaDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Naohiko AkimotoDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Masahiro SuzukiDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Kumiko KiritaDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Eriko KoizumiDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Hiroto NodaDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Teppei AkimotoDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Mitsuru KaiseDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Katsuhiko IwakiriDepartment of Gastroenterology, Nippon Medical School, Graduate School of Medicine, Tokyo, Japan.
Nippon Medical School · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimsThree-dimensional (3D) flexible endoscopy, a new imaging modality that provides a stereoscopic view, can facilitate endoscopic hand suturing (EHS), a novel intraluminal suturing technique. This ex-vivo pilot study evaluated the usefulness of 3D endoscopy in EHS.

methodsFour endoscopists (two certified, two non-certified) performed EHS in six sessions on a soft resin pad. Each session involved five stitches, under alternating 3D and two-dimensional (2D) conditions. Suturing time (sec/session), changes in suturing time, and accuracy of suturing were compared between 2D and 3D conditions.

resultsThe mean suturing time was shorter in 3D than in 2D (9.8±3.4 min/session vs. 11.2±5.1 min/session) conditions and EHS was completed faster in 3D conditions, particularly by non-certified endoscopists. The suturing speed increased as the 3D sessions progressed. Error rates (failure to grasp the needle, failure to thread the needle, and puncture retrial) in the 3D condition were lower than those in the 2D condition, whereas there was no apparent difference in deviation distance.

conclusion3D endoscopy may contribute to increasing the speed and accuracy of EHS in a short time period. Stereoscopic viewing during 3D endoscopy may help in efficient skill acquisition for EHS, particularly among novice endoscopists.

Indexed as

Endoscopic suturingLearning curveThree-dimensional endoscopy

Identifiers

PMID32336050
PMCPMC7280841
OpenAlexW3020677842

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked