Evidence map›Paper›PMID 32328763›Full record

ArticleEuropean radiology2020

High spatiotemporal resolution dynamic contrast-enhanced MRI improves the image-based discrimination of histopathology risk groups of peripheral zone prostate cancer: a supervised machine learning approach.

David J Winkel, Hanns-Christian Breit, Tobias K Block, Daniel T Boll, Tobias J Heye

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Correlation of KJournal for immunotherapy of cancer · 2024
    Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

David J WinkelDepartment of Radiology, University Hospital of Basel, 4031, Basel-Stadt, Switzerland. davidjean.winkel@usb.ch.
Hanns-Christian BreitDepartment of Radiology, University Hospital of Basel, 4031, Basel-Stadt, Switzerland.
Tobias K BlockDepartment of Radiology, University Hospital of Basel, 4031, Basel-Stadt, Switzerland.
Daniel T BollDepartment of Radiology, University Hospital of Basel, 4031, Basel-Stadt, Switzerland.
Tobias J HeyeDepartment of Radiology, University Hospital of Basel, 4031, Basel-Stadt, Switzerland.
University Hospital of Basel · CHAdvanced Imaging Research (United States) · US

Funding

Research Fund Junior Researchers of the University Hospital Basel 3MS1034
6 · The paper itself

Abstract

objectiveTo assess if adding perfusion information from dynamic contrast-enhanced (DCE MRI) acquisition schemes with high spatiotemporal resolution to T2w/DWI sequences as input features for a gradient boosting machine (GBM) machine learning (ML) classifier could better classify prostate cancer (PCa) risk groups than T2w/DWI sequences alone. MATERIALS AND

methodsOne hundred ninety patients (68 ± 9 years) were retrospectively evaluated at 3T MRI for clinical suspicion of PCa. Included were 201 peripheral zone (PZ) PCa lesions. Histopathological confirmation on fusion biopsy was matched with normal prostate parenchyma contralaterally. Biopsy results were grouped into benign tissue and low-, intermediate-, and high-risk groups (Gleason sum score 6, 7, and > 7, respectively). DCE MRI was performed using golden-angle radial sparse MRI. Perfusion maps (K

resultsFor the classification of benign vs. malignant and intermediate- vs. high-grade PCa, perfusion information added relevant information (AUC values 1 vs. 0.953 and 0.909 vs. 0.700, p < 0.001 and p = 0.038), while no statistically significant effect was found for low- vs. intermediate- and high-grade PCa.

conclusionPerfusion information from DCE MRI acquisition schemes with high spatiotemporal resolution to ML classifiers enables a superior risk stratification between benign and malignant and intermediate- and high-risk PCa in the PZ compared with classifiers based on T2w/DWI information alone. KEY POINTS: • In the recent guidelines, the role of DCE MRI has changed from a mandatory to recommended sequence. • DCE MRI acquisition schemes with high spatiotemporal resolution (e.g., GRASP) have been shown to improve the diagnostic performance compared with conventional DCE MRI sequences. • Using perfusion information acquired with GRASP in combination with ML classifiers significantly improved the prediction of benign vs. malignant and intermediate- vs. high-grade peripheral zone prostate cancer compared with non-contrast sequences.

Indexed as

Supervised Machine LearningAgedContrast MediaDiffusion Magnetic Resonance ImagingHumansImage-Guided BiopsyMaleNeoplasm StagingProstatic NeoplasmsRetrospective StudiesROC CurveContrast MediaImage-guided biopsyMachine learningMagnetic resonance imagingProstatic neoplasms

Identifiers

PMID32328763
OpenAlexW3019280549

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.