Evidence map›Paper›PMID 32326291›Full record

ArticleDiagnostics (Basel, Switzerland)2020

Fast Phase-Contrast Cine MRI for Assessing Intracranial Hemodynamics and Cerebrospinal Fluid Dynamics.

Naoki Ohno, Tosiaki Miyati, Tomohiro Noda, Noam Alperin, Takashi Hamaguchi, Masako Ohno, Tatsuhiko Matsushita, Mitsuhito Mase, Toshifumi Gabata, Satoshi Kobayashi

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.0field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 36 citations in OpenAlex.

  1. Computational Fluid Dynamics of Cerebrospinal Fluid.Advances in experimental medicine and biology · 2024
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 2 countries.

Naoki OhnoFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 9200942, Ishikawa, Japan.
Tosiaki MiyatiFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 9200942, Ishikawa, Japan.
Tomohiro NodaDepartment of Radiology, Kobe University Hospital, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 6500017, Hyogo, Japan.
Noam AlperinDepartment of Radiology, University of Miami, 1150 NW 14th Street, Suite 713, Miami, FL 33136, USA.
Takashi HamaguchiDepartment of Radiological Technology, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa 9208641, Ishikawa, Japan.
Masako OhnoDepartment of Radiological Technology, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa 9208641, Ishikawa, Japan.
Tatsuhiko MatsushitaDivision of Clinical Radiology Service, Kyoto University Hospital, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 6068507, Japan.
Mitsuhito MaseDepartment of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, 1-Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 4678601, Aichi, Japan.
Toshifumi GabataDepartment of Radiology, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa 9208641, Ishikawa, Japan.
Satoshi KobayashiFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 9200942, Ishikawa, Japan.
Kanazawa University · JPKanazawa University Hospital · JPKobe University Hospital · JPKyoto University Hospital · JPNagoya City University · JPUniversity of Miami · US

Funding

Japan Society for the Promotion of Science 18KK0450
6 · The paper itself

Abstract

We propose fast phase-contrast cine magnetic resonance imaging (PC-cine MRI) to allow breath-hold acquisition, and we compared intracranial hemo- and hydrodynamic parameters obtained during breath holding between full inspiration and end expiration. On a 3.0 T MRI, using electrocardiogram (ECG)-synchronized fast PC-cine MRI with parallel imaging, rectangular field of view, and segmented k-space, we obtained velocity-mapped phase images at the mid-C2 level with different velocity encoding for transcranial blood flow and cerebrospinal-fluid (CSF) flow. Next, we calculated the peak-to-peak amplitudes of cerebral blood flow (ΔCBF), cerebral venous outflow, intracranial volume change, CSF pressure gradient (ΔPG), and intracranial compliance index. These parameters were compared between the proposed and conventional methods. Moreover, we compared these parameters between different utilized breath-hold maneuvers (inspiration, expiration, and free breathing). All parameters derived from the fast PC method agreed with those from the conventional method. The ΔPG was significantly higher during full inspiration breath holding than at the end of expiration and during free breathing. The proposed fast PC-cine MRI reduced scan time (within 30 s) with good agreement with conventional methods. The use of this method also makes it possible to assess the effects of respiration on intracranial hemo- and hydrodynamics.

Indexed as

cerebrospinal fluid hydrodynamicsintracranial hemodynamicsphase-contrastrespiration.

Identifiers

PMID32326291
PMCPMC7236008
OpenAlexW3019808316

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.