A Smart Rig for Calibration of Gas Sensor Nodes.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measurements. This paper proposes a dedicated smart calibration rig with a set of novel features enabling simultaneous calibration of multiple sensors. The proposed calibration rig system comprises a gas mixing system, temperature control system, a test chamber, and a process-control PC that controls all calibration phases. The calibration process is automated by a LabVIEW-based platform that controls the calibration environment for the sensor nodes, logs sensor data, and best fit equation based on interpolation for every sensor on the node and uploads it to the sensor node for next deployments. The communication between the PC and the sensor nodes is performed using the same IEEE 802.15.4 (ZigBee) protocol that the nodes also use in field deployment for air quality measurement. The results presented demonstrate the effectiveness of the sensors calibration rig.