Evidence map›Paper›PMID 32325667›Full record

ArticleMaterials (Basel, Switzerland)2020

Relevant Design Aspects to Improve the Stability of Titanium Dental Implants.

M Herrero-Climent, P López-Jarana, B F Lemos, F J Gil, C Falcão, J V Ríos-Santos, B Ríos-Carrasco

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Trial
  2. Clinical outcomes of a two-piece zirconia dental implant system.International journal of implant dentistry · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. The Influence of Implant Macro-geometry in Primary Stability in Low-Density Bone: AnJournal of International Society of Preventive & Community Dentistry
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

M Herrero-ClimentPorto Dental Institute, 4150-518 Porto, Portugal.
P López-JaranaPorto Dental Institute, 4150-518 Porto, Portugal.
B F LemosPorto Dental Institute, 4150-518 Porto, Portugal.ORCID 0000-0002-9896-5139
F J GilFaculty of Dentistry, Bioengineering Institute of Technology, International University of Catalonia, 08017 Barcelona, Spain.
C FalcãoPorto Dental Institute, 4150-518 Porto, Portugal.
J V Ríos-SantosDepartment of Periodontology, University of Seville, 41009 Seville, Spain.ORCID 0000-0002-8121-6166
B Ríos-CarrascoDepartment of Periodontology, University of Seville, 41009 Seville, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Post-extractional implants and immediate loading protocols are becoming much more frequent in everyday clinical practice. Given the existing literature about tapered implants, the objective of this paper was to understand whether implant shape had a direct influence on the results of the insertion torque (IT) and implant stability quotient (ISQ). Seven tapered implant prototypes were developed and distributed into three groups and compared with a control cylindrical implant-VEGA by Klockner Implant System. The implants were inserted into bovine bone type III according to Lekholm and Zarb Classification. The sample size was n = 30 for the three groups. Final IT was measured with a torquemeter, and the ISQ was measured with Penguin Resonance Frequency Analysis (RFA). Modifications done to the Prototype I did not reveal higher values of the ISQ and IT when compared to VEGA. In the second group, when comparing the five prototypes (II-VI) with VEGA, it was seen that the values of the ISQ and IT were not always higher, but there were two values of the ISQ that were statistically significantly higher with the 4.0 mm diameter Prototypes II (76.3 ± 6.1) and IV (78 ± 3.7). Prototype VII was the one with higher and significant values of the ISQ and IT. In both diameters and in both variables, all differences were statistically significant enough to achieve the higher values of primary stability values (IT and ISQ). Given the limitations of this study, it can be concluded that when there is an increase of the diameter of the implant and body taper, there is an increase of the ISQ and IT, showing that the diameter of the implant is an important criteria to obtain higher values of primary stability.

Indexed as

dental implantimmediate loadingimplant designinsertion torqueISQRFAtapered implant

Identifiers

PMID32325667
PMCPMC7216269

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.