ArticleJournal of ultrasonography2020
Optimization of diagnostic ultrasonography of the gallbladder based on own experience and literature.
Article in Journal of ultrasonography, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- A-SEE2.0: Active-Sensing End-Effector for Robotic Ultrasound Systems with Dense Contact Surface Perception Enabled Probe Orientation Adjustment.IEEE robotics and automation letters · 2025Article
- Article
- Sonographic gallbladder wall thickness measurement and the prediction of esophageal varices among cirrhotics.World journal of hepatology · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although transabdominal imaging of the gallbladder has become a gold standard, new light should be shed on some aspects, which will prove useful in everyday practice. Therefore, based on our own experience and the available literature, we would like to draw attention to those elements of gallbladder ultrasound imaging which may increase its diagnostic efficacy. The paper draws attention to the difficulty in assessing certain anatomical structures, such as the inferior wall, the bottom and the region of the neck of the gallbladder, and offers ways to improve their imaging. We also emphasized the negative effects of duodenal and transverse colon (along with their contents) adhesion to the bottom of the gallbladder on the correct diagnosis. Due to the importance of size in the management strategy for detected gallbladder polyps, we suggest their measurement on an image enlarged with the zoom function. This technique also allows for an accurate assessment of the shape and echostructure of these lesions. An enlarged image of a polyp makes it possible to trace its behavior in time. We also remind that the hepatic wall of the gallbladder is the only site allowing for a reliable wall thickness measurement. We also pointed to the importance of changing patient's position when assessing the mobility and the nature of lesions. Altering patient's position during examination may help detect anomalies in the form of a floating gallbladder, which may promote its torsion. Finally, pathologies whose diagnosis may be facilitated by color-coded blood flow imaging are also presented. The issues discussed in this paper are only a fraction of problems faced by an ultrasound operator in the field of gallbladder diagnostic imaging. However, the proposed ultrasound approaches should help solve some of these problems in everyday practice. Although transabdominal imaging of the gallbladder has become a gold standard, new light should be shed on some aspects, which will prove useful in everyday practice. Therefore, based on our own experience and the available literature, we would like to draw attention to those elements of gallbladder ultrasound imaging which may increase its diagnostic efficacy. The paper draws attention to the difficulty in assessing certain anatomical structures, such as the inferior wall, the bottom and the region of the neck of the gallbladder, and offers ways to improve their imaging. We also emphasized the negative effects of duodenal and transverse colon (along with their contents) adhesion to the bottom of the gallbladder on the correct diagnosis. Due to the importance of size in the management strategy for detected gallbladder polyps, we suggest their measurement on an image enlarged with the zoom function. This technique also allows for an accurate assessment of the shape and echostructure of these lesions. An enlarged image of a polyp makes it possible to trace its behavior in time. We also remind that the hepatic wall of the gallbladder is the only site allowing for a reliable wall thickness measurement. We also pointed to the importance of changing patient’s position when assessing the mobility and the nature of lesions. Altering patient’s position during examination may help detect anomalies in the form of a floating gallbladder, which may promote its torsion. Finally, pathologies whose diagnosis may be facilitated by color-coded blood flow imaging are also presented. The issues discussed in this paper are only a fraction of problems faced by an ultrasound operator in the field of gallbladder diagnostic imaging. However, the proposed ultrasound approaches should help solve some of these problems in everyday practice.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.