Evidence map›Paper›PMID 32316211›Full record

ArticleSensors (Basel, Switzerland)2020

Impact of Self-Assembled Monolayer Design and Electrochemical Factors on Impedance-Based Biosensing.

Michael C Brothers, David Moore, Michael St Lawrence, Jonathan Harris, Ronald M Joseph, Erin Ratcliff, Oscar N Ruiz, Nicholas Glavin, Steve S Kim

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 46 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Real-Time,ACS sensors · 2022
    Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Michael C Brothers711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson AFB, OH 45433, USA.ORCID 0000-0002-8239-2399
David MooreUES Inc., Dayton 45432, OH, USA.
Michael St LawrenceAerospace Systems Directorate, Air Force Research Laboratory, Wright-Patterson AFB, OH 45433, USA.
Jonathan Harris711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson AFB, OH 45433, USA.
Ronald M JosephUES Inc., Dayton 45432, OH, USA.
Erin RatcliffDepartment of Chemical Engineering, University of Arizona, Tucson, AZ 85721, USA.
Oscar N RuizAerospace Systems Directorate, Air Force Research Laboratory, Wright-Patterson AFB, OH 45433, USA.
Nicholas GlavinMaterials and Manufacturing Directorate, Air Force Research Laboratory, Wright-Patterson AFB, OH 45433, USA.
Steve S Kim711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson AFB, OH 45433, USA.ORCID 0000-0002-9519-077X
United States Air Force Research Laboratory · USUniversity of Arizona · USUniversity of Dayton · US

Funding

Air Force Research Laboratory Civilian Research and Development Fund
6 · The paper itself

Abstract

Real-time sensing of proteins, especially in wearable devices, remains a substantial challenge due to the need to convert a binding event into a measurable signal that is compatible with the chosen analytical instrumentation. Impedance spectroscopy enables real-time detection via either measuring electrostatic interactions or electron transfer reactions while simultaneously being amenable to miniaturization for integration into wearable form-factors. To create a more robust methodology for optimizing impedance-based sensors, additional fundamental studies exploring components influencing the design and implementation of these sensors are needed. This investigation addresses a sub-set of these issues by combining optical and electrochemical characterization to validate impedance-based sensor performance as a function of (1) biorecognition element density, (2) self-assembled monolayer chain length, (3) self-assembled monolayer charge density, (4) the electrochemical sensing mechanism and (5) the redox reporter selection. Using a pre-existing lysozyme aptamer and lysozyme analyte combination, we demonstrate a number of design criteria to advance the state-of-the-art in protein sensing. For this model system we demonstrated the following: First, denser self-assembled monolayers yielded substantially improved sensing results. Second, self-assembled monolayer composition, including both thickness and charge density, changed the observed peak position and peak current. Third, single frequency measurements, while less informative, can be optimized to replace multi-frequency measurements and in some cases (such as that with zwitterionic self-assembled monolayers) are preferred. Finally, various redox reporters traditionally not used in impedance sensing should be further explored. Collectively, these results can help limit bottlenecks associated with device development, enabling realization of next-generation impedance-based biosensing with customize sensor design for the specific application.

Indexed as

Aptamers, PeptideBiosensing TechniquesBromidesDielectric SpectroscopyElectrochemical TechniquesElectrodesEquipment DesignMethylene BlueMuramidaseQuaternary Ammonium CompoundsSulfhydryl Compounds(6-mercaptohexyl) trimethylammonium bromideAptamers, PeptideBromidesMethylene BlueMuramidaseQuaternary Ammonium CompoundsSulfhydryl Compoundselectrochemical impedance spectroscopyimpedance biosensorprotein sensorself-assembled monolayer

Identifiers

PMID32316211
PMCPMC7218866
OpenAlexW3016807995

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.