Evidence map›Paper›PMID 32313220›Full record

ArticleNature nanotechnology2020

Three-dimensional localization microscopy in live flowing cells.

Lucien E Weiss, Yael Shalev Ezra, Sarah Goldberg, Boris Ferdman, Omer Adir, Avi Schroeder, Onit Alalouf, Yoav Shechtman

Abstract read
PubMed Publisher
In one paragraph

Article in Nature nanotechnology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. LFC-Lab on a chip · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Lucien E WeissDepartment of Biomedical Engineering and Lorry I, Lokey Interdisciplinary Centre for Life Sciences and Engineering, Technion, Haifa, Israel. Lucien.e.weiss@gmail.com.ORCID http://orcid.org/0000-0002-0971-7329
Yael Shalev EzraDepartment of Biomedical Engineering and Lorry I, Lokey Interdisciplinary Centre for Life Sciences and Engineering, Technion, Haifa, Israel.
Sarah GoldbergDepartment of Biomedical Engineering and Lorry I, Lokey Interdisciplinary Centre for Life Sciences and Engineering, Technion, Haifa, Israel.
Boris FerdmanDepartment of Biomedical Engineering and Lorry I, Lokey Interdisciplinary Centre for Life Sciences and Engineering, Technion, Haifa, Israel.
Omer AdirRussell Berrie Nanotechnology Institute, Technion, Haifa, Israel.
Avi SchroederDepartment of Chemical Engineering, Technion, Haifa, Israel.
Onit AlaloufDepartment of Biomedical Engineering and Lorry I, Lokey Interdisciplinary Centre for Life Sciences and Engineering, Technion, Haifa, Israel.
Yoav ShechtmanDepartment of Biomedical Engineering and Lorry I, Lokey Interdisciplinary Centre for Life Sciences and Engineering, Technion, Haifa, Israel. yoavsh@bm.technion.ac.il.ORCID http://orcid.org/0000-0001-8498-5203

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Capturing the dynamics of live cell populations with nanoscale resolution poses a significant challenge, primarily owing to the speed-resolution trade-off of existing microscopy techniques. Flow cytometry would offer sufficient throughput, but lacks subsample detail. Here we show that imaging flow cytometry, in which the point detectors of flow cytometry are replaced with a camera to record 2D images, is compatible with 3D localization microscopy through point-spread-function engineering, which encodes the depth of the emitter into the emission pattern captured by the camera. The extraction of 3D positions from sub-cellular objects of interest is achieved by calibrating the depth-dependent response of the imaging system using fluorescent beads mixed with the sample buffer. This approach enables 4D imaging of up to tens of thousands of objects per minute and can be applied to characterize chromatin dynamics and the uptake and spatial distribution of nanoparticles in live cancer cells.

Indexed as

Equipment DesignFlow CytometryHumansImaging, Three-DimensionalMicroscopy, FluorescenceNanoparticlesOptical ImagingSaccharomyces cerevisiaeT-Lymphocytes

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.