Evidence map›Paper›PMID 32313067›Full record

ArticleNature communications2020

Real-time non-contact cellular imaging and angiography of human cornea and limbus with common-path full-field/SD OCT.

Viacheslav Mazlin, Peng Xiao, Jules Scholler, Kristina Irsch, Kate Grieve, Mathias Fink, A Claude Boccara

Open access · goldAbstract read
In one paragraph

Article in Nature communications, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 41 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Frontiers in ophthalmology · 2025
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Non-invasiveBiomedical optics express · 2023
    Article
  13. Article
  14. Review
  15. N-mirror Robot System for Laser Surgery: A Simulation Study.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2023
    Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Line-scanning SD-OCT forBiomedical optics express · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 2 countries.

Viacheslav MazlinInstitut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France. mazlin.slava@gmail.com.ORCID http://orcid.org/0000-0002-1982-8313
Peng XiaoInstitut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France. xiaopengaddis@hotmail.com.ORCID http://orcid.org/0000-0002-2860-0249
Jules SchollerInstitut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France.ORCID http://orcid.org/0000-0002-1890-5938
Kristina IrschVision Institute/CIC 1423, Sorbonne University, UMR_S 968/INSERM, U968/CNRS, UMR_7210, 17 Rue Moreau, 75012, Paris, France.
Kate GrieveVision Institute/CIC 1423, Sorbonne University, UMR_S 968/INSERM, U968/CNRS, UMR_7210, 17 Rue Moreau, 75012, Paris, France.
Mathias FinkInstitut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France.ORCID http://orcid.org/0000-0002-8494-7562
A Claude BoccaraInstitut Langevin, ESPCI Paris, PSL University, CNRS, 1 Rue Jussieu, 75005, Paris, France. claude.boccara@espci.fr.
Centre National de la Recherche Scientifique · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In today's clinics, a cell-resolution view of the cornea can be achieved only with a confocal microscope (IVCM) in contact with the eye. Here, we present a common-path full-field/spectral-domain OCT microscope (FF/SD OCT), which enables cell-detail imaging of the entire ocular surface in humans (central and peripheral cornea, limbus, sclera, tear film) without contact and in real-time. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images contain cells and nerves, which can be quantified over a millimetric field-of-view, beyond the capability of IVCM and conventional OCT. In the limbus, palisades of Vogt, vessels, and blood flow can be resolved with high contrast without contrast agent injection. The fast imaging speed of 275 frames/s (0.6 billion pixels/s) allows direct monitoring of blood flow dynamics, enabling creation of high-resolution velocity maps. Tear flow velocity and evaporation time can be measured without fluorescein administration.

Indexed as

AdultAngiographyBiomedical EngineeringBlood Flow VelocityCorneaEquipment DesignFemaleHumansLimbus CorneaeMaleMicroscopyOptical ImagingSoftwareTomography, Optical CoherenceYoung Adult

Identifiers

PMID32313067
PMCPMC7171111
OpenAlexW3001297293

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.