Evidence map›Paper›PMID 32312298›Full record

ArticleJournal of orthopaedic surgery and research2020

Nailing of diaphyseal ulna fractures in adults-biomechanical evaluation of a novel implant in comparison with locked plating.

Johannes Christof Hopf, Dorothea Mehler, Tobias Eckhard Nowak, Dominik Gruszka, Daniel Wagner, Pol Maria Rommens

Open access · goldAbstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Comparison of a 2.7-mm and 3.5-mm locking compression plate for ulnar fractures: a biomechanical evaluation.OTA international : the open access journal of orthopaedic trauma · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Johannes Christof HopfDepartment of Orthopedics and Trauma Surgery, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany. joh.hopf@gmail.com.ORCID https://orcid.org/0000-0001-9281-3428
Dorothea MehlerDepartment of Orthopedics and Trauma Surgery, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Tobias Eckhard NowakDepartment of Orthopedics and Trauma Surgery, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Dominik GruszkaDepartment of Orthopedics and Trauma Surgery, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Daniel WagnerDepartment of Orthopedics and Trauma Surgery, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Pol Maria RommensDepartment of Orthopedics and Trauma Surgery, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Johannes Gutenberg University Mainz · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdult forearm fractures require surgical treatment in most cases. Open reduction and internal fixation with plate osteosynthesis is the therapy of choice. Intramedullary fixation offers several advantages compared to plate fixation but is not routinely used. The aim of our study was to compare a newly designed ulna nail with angular stable plating in a biomechanical testing setup of an ulna shaft fracture with a diaphyseal defect.

methodsTen pairs of sawbones with a defect osteotomy of the ulna shaft (OTA 2U2C3) were fixed with an interlocked nail or locked plate osteosynthesis. The constructs were tested under four-point bending, torsional loading and axial loading in a servo-pneumatic testing machine to compare the stiffness of both stabilization methods.

resultsThe nail constructs show lower yet sufficient bending stiffness (62.25 ± 6.64 N/mm) compared to the plate constructs (71.2 ± 5.98 N/mm, p = 0.005). The torsional loading test shows superior stiffness of the plate constructs (0.24 ± 0.03 Nm/deg vs. 0.1 ± 0.01 Nm/deg; p < 0.001), while the axial loading shows superior stiffness of the nail constructs (1028.9 ± 402.1 N/mm vs. 343.9 ± 112.6 N/mm; p < 0.001).

conclusionsIntramedullary nailing of ulna shaft fractures obtains sufficient but lower stability in bending and torsional loading when compared to rigid angular stable plating and could be an alternative technique to plate fixation. The lower stability and the closed stabilization technique allow for a rapid periosteal healing, which is not present in stiffer constructs.

Indexed as

Bone NailsBone PlatesAdultBiomechanical PhenomenaDiaphysesFracture Fixation, IntramedullaryHumansTorsion, MechanicalUlna FracturesWeight-BearingBiomechanical studyNailingUlna shaft

Identifiers

PMID32312298
PMCPMC7169040
OpenAlexW3017270205

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.