Evidence map›Paper›PMID 32309720›Full record

ArticleACS omega2020

In Vitro Investigation of Hemocompatibility of Hydrothermally Treated Titanium and Titanium Alloy Surfaces.

Vignesh K Manivasagam, Ketul C Popat

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 53 citations in OpenAlex.

  1. Review
  2. The dental implant surface: a review of the past, present and future.Journal of materials science. Materials in medicine · 2026
    Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Hydrothermally treated titanium surfaces for enhanced osteogenic differentiation of adipose derived stem cells.Materials science & engineering. C, Materials for biological applications · 2021
    Article
  18. Review
  19. Improved hemocompatibility and reduced bacterial adhesion on superhydrophobic titania nanoflower surfaces.Materials science & engineering. C, Materials for biological applications · 2021
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Vignesh K ManivasagamDepartment of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.
Ketul C PopatDepartment of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.
Colorado State University · US

Funding

Superhydrophobic Heart Valve ProsthesisR01HL135505 · NHLBI · OHIO STATE UNIVERSITY · PI DASI, LAKSHMI PRASAD, KOTA, ARUN KUMAR · 2017 to 2020
$2.9M
Superomniphobic flow controlled prosthetic heart valveR21HL139208 · NHLBI · OHIO STATE UNIVERSITY · PI DASI, LAKSHMI PRASAD, KOTA, ARUN KUMAR · 2018 to 2019
$408k
NHLBI NIH HHS R01 HL135505NHLBI NIH HHS R21 HL139208
6 · The paper itself

Abstract

For decades, titanium and its alloys have been established as a biocompatible material for cardiovascular medical devices such as heart valves, stents, vascular grafts, catheters, etc. However, thrombosis is one of the reasons for implant failure, where blood clot forms on the implant surface, thus obstructing the flow of the blood and that leads to some serious complications. Various surface modification techniques such as heparin modification, albumin coating, surface anodization, plasma etching, and hydrothermal treatments have been explored to improve the hemocompatibility of titanium-based materials. However, there are several limitations related to the robustness of the surfaces and long-term efficacy in vivo. In this study, titanium and its alloy Ti-6Al-4V were hydrothermally treated to form nanostructured surfaces with the aim to enhance their hemocompatibility. These modified surfaces were characterized for their wettability, surface morphology, surface chemistry, and crystallinity. The hemocompatibility of these surfaces was characterized by evaluating blood plasma protein adsorption, platelet adhesion and activation, platelet-leukocyte complex formation, and whole blood clotting. The results indicate lower fibrinogen adsorption, cell adhesion, platelet activation, and whole blood clotting on hydrothermally treated surfaces. Thus, these surfaces may be a promising approach to prevent thrombosis for several titanium blood-contacting medical devices.

Identifiers

PMID32309720
PMCPMC7161035
OpenAlexW3014351289

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.