Evidence map›Paper›PMID 32307904›Full record

ArticleESC heart failure2020

Intra-aortic balloon pump: is the technique really outdated?

Mariama Akodad, Clément Delmas, Laurent Bonello, Claire Duflos, François Roubille

Open access · goldAbstract read
In one paragraph

Article in ESC heart failure, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Mariama AkodadDepartment of Cardiology, Montpellier University Hospital, 34295, Montpellier, Cedex 5, France.
Clément DelmasIntensive Cardiac Care Unit, Cardiology Department, University Hospital of Rangueil, 31059, Toulouse, France.
Laurent BonelloDepartment of Cardiology, Intensive Care Unit, Aix-Marseille Université, Assistance Publique-Hôpitaux de Marseille, Hôpital Nord, Marseille, France.
Claire DuflosDepartment of Medical Information, Montpellier University Hospital, 34295, Montpellier, Cedex 5, France.
François RoubilleDepartment of Cardiology, Montpellier University Hospital, 34295, Montpellier, Cedex 5, France.
Centre National de la Recherche Scientifique · FRAix-Marseille Université · FRCentre Hospitalier Universitaire de Toulouse · FRUniversité de Montpellier · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsIntra-aortic balloon pump (IABP) utilization was expected to be quickly abandoned following the IABP-shock trial and its class III, level B recommendation in the 2016 European Society of Cardiology (ESC) guidelines. The aim of this study was to evaluate the use of IABP compared with other mechanical support devices in a nationwide approach. METHODS AND

resultsWe conducted a retrospective study based on the French national hospital discharge database. All patients undergoing assist device implantation by IABP, extracorporeal membrane oxygenation (ECMO), or IMPELLA® from 2014 to 2018 (2 years before/2 years after the 2016 guidelines) were included. The primary endpoint was the incidence of IABP implantation over the years. Secondary endpoints were incidence of total assist device, ECMO, and IMPELLA® implantations. From 2014 to 2018, a total of 18 940 patients benefited from mechanical support by IABP (n = 6657, 35.2%), ECMO (n = 11 881, 62.7%), or IMPELLA® (n = 402, 2.1%) in France. The incidence of total mechanical support implantations (ECMO and IABP) was constant over the years. IABP implantations decreased progressively from 1725 implantations in 2014 to 996 in 2018 (-42%). By contrast, ECMO implantations increased progressively from 1919 implantations in 2014 to 2763 implantations in 2018 (+44%). IMPELLA® implantations remained stable over the years from 63 (1.7%) implantations in 2014 to 83 (2.1%) in 2018.

conclusionsIn this nationwide real-life study, despite a significant decline in IABP implantations over the years since the ESC guidelines, this device remained used in clinical practice with around 1000 implantations in 2018. The size of centres was not strictly correlated with this use, suggesting differential uses depending on the local background.

Indexed as

Heart-Assist DevicesShock, CardiogenicFranceHumansIntra-Aortic Balloon PumpingRetrospective StudiesCardiogenic shockExtracorporeal membrane oxygenation (ECMO)Intra-aortic balloon pump (IABP)Mechanical support

Identifiers

PMID32307904
PMCPMC7261556
OpenAlexW3017126646

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.