ArticleMagnetic resonance in medicine2020
Impact of gradient imperfections on bone water quantification with UTE MRI.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 9 citations in OpenAlex.
- "Two-For-One": 4D Cardiac and Pulmonary MR Imaging From a Single Acquisition Using bSTAR.Magnetic resonance in medicine · 2026Trial
- Feasibility of free-breathing 0.55-T lung MRI for structural and functional characterization in preterm infants with bronchopulmonary dysplasia.Pediatric radiology · 2026Article
- Comparison of bi- and tri-component approaches for the analysis of short-TMagma (New York, N.Y.) · 2026Article
- Free-breathing 3D pulmonary ventilation mapping at 0.55 T using stack-of-spiral out-in bSSFP.Magnetic resonance in medicine · 2026Article
- Three contrasts in 3 min: Rapid, high-resolution, and bone-selective UTE MRI for craniofacial imaging with automated deep-learning skull segmentation.Magnetic resonance in medicine · 2025Article
- Replication of the bSTAR sequence and open-source implementation.Magnetic resonance in medicine · 2024Article
- Article
- Efficient gradient waveform measurements with variable-prephasing.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2021Article
- Article
- Field camera versus phantom-based measurement of the gradient system transfer function (GSTF) with dwell time compensation.Magnetic resonance imaging · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
purposeThe impact of gradient imperfections on UTE images and UTE image-derived bone water quantification was investigated at 3 T field strength.
methodsThe effects of simple gradient time delays and eddy currents on UTE images, as well as the effects of gradient error corrections, were studied with simulation and phantom experiments. The k-space trajectory was mapped with a 2D sequence with phase encoding on both spatial axes by measuring the phase of the signal in small time increments during ramp-up of the read gradient. In vivo 3D UTE images were reconstructed with and without gradient error compensation to determine the bias in bone water quantification. Finally, imaging was performed on 2 equally configured Siemens TIM Trio systems (Siemens Medical Solutions, Erlangen, Germany) to investigate the impact of such gradient imperfections on inter-scanner measurement bias.
resultsCompared to values derived from UTE images with full gradient error compensation, total bone water was found to deviate substantially with no (up to 17%) or partial (delay-only) compensation (up to 10.8%). Bound water, obtained with inversion recovery-prepared UTE, was somewhat less susceptible to gradient errors (up to 2.2% for both correction strategies). Inter-scanner comparison indicated a statistically significant bias between measurements from the 2 MR systems for both total and bound water, which either vanished or was substantially reduced following gradient error correction.
conclusionGradient imperfections impose spatially dependent artifacts on UTE images, which compromise not only bone water quantification accuracy but also inter-scanner measurement agreement if left uncompensated.