Impact of gradient imperfections on bone water quantification with UTE MRI.

Xia Zhao, Hyunyeol Lee, Hee Kwon Song, Cheng-Chieh Cheng, Felix W Wehrli

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Efficient gradient waveform measurements with variable-prephasing.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2021
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Xia ZhaoDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Hyunyeol LeeDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.ORCID 0000-0002-3941-6578
Hee Kwon SongDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Cheng-Chieh ChengDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.ORCID 0000-0001-5833-5661
Felix W WehrliDepartment of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.ORCID 0000-0003-3430-1840
University of Pennsylvania · US

Funding

Bone Water &Mineralization: Nuclear Magnetic ResonanceR01AR050068 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI WEHRLI, FELIX W · 2003 to 2022
$4.9M
NIAMS NIH HHS R01 AR050068
6 · The paper itself

Abstract

purposeThe impact of gradient imperfections on UTE images and UTE image-derived bone water quantification was investigated at 3 T field strength.

methodsThe effects of simple gradient time delays and eddy currents on UTE images, as well as the effects of gradient error corrections, were studied with simulation and phantom experiments. The k-space trajectory was mapped with a 2D sequence with phase encoding on both spatial axes by measuring the phase of the signal in small time increments during ramp-up of the read gradient. In vivo 3D UTE images were reconstructed with and without gradient error compensation to determine the bias in bone water quantification. Finally, imaging was performed on 2 equally configured Siemens TIM Trio systems (Siemens Medical Solutions, Erlangen, Germany) to investigate the impact of such gradient imperfections on inter-scanner measurement bias.

resultsCompared to values derived from UTE images with full gradient error compensation, total bone water was found to deviate substantially with no (up to 17%) or partial (delay-only) compensation (up to 10.8%). Bound water, obtained with inversion recovery-prepared UTE, was somewhat less susceptible to gradient errors (up to 2.2% for both correction strategies). Inter-scanner comparison indicated a statistically significant bias between measurements from the 2 MR systems for both total and bound water, which either vanished or was substantially reduced following gradient error correction.

conclusionGradient imperfections impose spatially dependent artifacts on UTE images, which compromise not only bone water quantification accuracy but also inter-scanner measurement agreement if left uncompensated.

Indexed as

Magnetic Resonance ImagingWaterGermanyImaging, Three-DimensionalPhantoms, ImagingWaterbone watergradient delaysk-space trajectory correctionUTE

Identifiers

PMID32307749
PMCPMC7348668
OpenAlexW3017360119

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.