Characterization of dimensional, morphological and morphometric features of retrieved 3D-printed acetabular cups for hip arthroplasty.

Lorenzo Dall'Ava, Harry Hothi, Johann Henckel, Anna Di Laura, Paul Shearing, Alister Hart

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Lorenzo Dall'AvaInstitute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore, HA7 4LP, UK. lorenzo.dallava.17@ucl.ac.uk.
Harry HothiRoyal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
Johann HenckelRoyal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
Anna Di LauraRoyal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
Paul ShearingElectrochemical Innovation Lab, Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK.
Alister HartRoyal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
University College London · GBRoyal National Orthopaedic Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThree-dimensional (3D) printing of porous titanium implants is increasing in orthopaedics, promising enhanced bony fixation whilst maintaining design similarities with conventionally manufactured components. Our study is one of the first to non-destructively characterize 3D-printed implants, using conventionally manufactured components as a reference.

methodsWe analysed 16 acetabular cups retrieved from patients, divided into two groups: '3D-printed' (n = 6) and 'conventional' (n = 10). Coordinate-measuring machine (CMM), electron microscopy (SEM) and microcomputed tomography (micro-CT) were used to investigate the roundness of the internal cup surface, the morphology of the backside surface and the morphometric features of the porous structures of the cups, respectively. The amount of bony attachment was also evaluated.

resultsCMM analysis showed a median roundness of 19.45 and 14.52 μm for 3D-printed and conventional cups, respectively (p = 0.1114). SEM images revealed partially molten particles on the struts of 3D-printed implants; these are a by-product of the manufacturing technique, unlike the beads shown by conventional cups. As expected, porosity, pore size, strut thickness and thickness of the porous structure were significantly higher for 3D-printed components (p = 0.0002), with median values of 72.3%, 915 μm, 498 μm and 1.287 mm (p = 0.0002). The median values of bony attachment were 84.9% and 69.3% for 3D-printed and conventional cups, respectively (p = 0.2635).

conclusion3D-printed implants are designed to be significantly more porous than some conventional components, as shown in this study, whilst still exhibiting the same shape and size. We found differences in the surface morphologies of the groups, related to the different manufacturing methods; a key finding was the presence of partially molten particles on the 3D-printed cups.

Indexed as

Hip ProsthesisAcetabulumAgedArthroplasty, Replacement, HipFemaleHumansMaleMiddle AgedPrinting, Three-DimensionalProsthesis DesignX-Ray Microtomography3D printingAdditive manufacturingHip arthroplastyOrthopaedic implantsPorous acetabular cups

Identifiers

PMID32306995
PMCPMC7169042
OpenAlexW3017232847

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.