Evidence map›Paper›PMID 32306530›Full record

ArticleJournal of applied clinical medical physics2020

A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.

Damodar Pokhrel, Justin Visak, Lana Sanford

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Damodar PokhrelDepartment of Radiation Medicine, Medical Physics Graduate Program, University of Kentucky, Lexington, KY, USA.
Justin VisakDepartment of Radiation Medicine, Medical Physics Graduate Program, University of Kentucky, Lexington, KY, USA.
Lana SanfordDepartment of Radiation Medicine, Medical Physics Graduate Program, University of Kentucky, Lexington, KY, USA.
University of Kentucky · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVolumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery uncertainties associated with small-field dosimetry error and interplay effects with small lesions. We describe and compare a clinically useful dynamic conformal arc (DCA)-based VMAT (d-VMAT) technique for lung SBRT using flattening filter free (FFF) beams to minimize these effects. MATERIALS AND

methodsTen solitary early-stage I-II non-small-cell lung cancer (NSCLC) patients were treated with a single dose of 30 Gy using 3-6 non-coplanar VMAT arcs (clinical VMAT) with 6X-FFF beams in our clinic. These clinically treated plans were re-optimized using a novel d-VMAT planning technique. For comparison, d-VMAT plans were recalculated using DCA with user-controlled field aperture shape before VMAT optimization. Identical beam geometry, dose calculation algorithm, grid size, and planning objectives were used. The clinical VMAT and d-VMAT plans were compared via RTOG-0915 protocol compliances for conformity, gradient indices, and dose to organs at risk (OAR). Additionally, treatment delivery efficiency and accuracy were recorded.

resultsAll plans met RTOG-0915 requirements. Comparing with clinical VMAT, d-VMAT plans gave similar target coverage with better target conformity, tighter radiosurgical dose distribution with lower gradient indices, and dose to OAR. Lower total number of monitor units and small beam modulation factor reduced beam-on time by 1.75 min (P < 0.001), on average (maximum up to 2.52 min). Beam delivery accuracy was improved by 2%, on average (P < 0.05) and maximum up to 6% in some cases for d-VMAT plans.

conclusionThis simple d-VMAT technique provided excellent plan quality, reduced intermediate dose-spillage, and dose to OAR while providing faster treatment delivery by significantly reducing beam-on time. This novel treatment planning approach will improve patient compliance along with potentially reducing intrafraction motion error. Moreover, with less MLC modulation through the target, d-VMAT could potentially minimize small-field dosimetry errors and MLC interplay effects. If available, d-VMAT planning approach is recommended for future clinical lung SBRT plan optimization.

Indexed as

Carcinoma, Non-Small-Cell LungLung NeoplasmsRadiosurgeryRadiotherapy, Intensity-ModulatedHumansLungPlanning TechniquesRadiotherapy DosageRadiotherapy Planning, Computer-AssistedDCA-based VMATFFF-beamlung SBRTsingle dose

Identifiers

PMID32306530
PMCPMC7386176
OpenAlexW3017179392

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked