Evidence map›Paper›PMID 32306132›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2021

The tibial cut in total knee arthroplasty influences the varus alignment, the femoral roll-back and the tibiofemoral rotation in patients with constitutional varus.

Martin Faschingbauer, S Hacker, A Seitz, L Dürselen, F Boettner, H Reichel

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Martin FaschingbauerDepartment of Orthopedic Surgery, RKU, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany. martin.faschingbauer@outlook.com.
S HackerInstitute of Orthopaedic Research and Biomechanics, University of Ulm, Helmholtzstraße 14, 89081, Ulm, Germany.
A SeitzInstitute of Orthopaedic Research and Biomechanics, University of Ulm, Helmholtzstraße 14, 89081, Ulm, Germany.
L DürselenInstitute of Orthopaedic Research and Biomechanics, University of Ulm, Helmholtzstraße 14, 89081, Ulm, Germany.
F BoettnerHospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
H ReichelDepartment of Orthopedic Surgery, RKU, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany.
Universität Ulm · DEHospital for Special Surgery · USTechnische Hochschule Ulm · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDifferent alignment types for a better outcome after TKA were described. However, it is not clear how kinematic alignment influences knee joint kinematic. The purpose of this study was to analyze whether adapted tibial cuts in constitutional varus knees affect knee joint kinematics regarding femoral roll-back, varus/valgus angle, and femorotibial rotation.

methodsSeven cadaveric knees with constitutional varus alignment were examined in the native state and after implantation of a cruciate retaining (CR)-TKA with 0°, 3° and 6° tibia cuts using an established knee joint simulator. The effects of varus alignment on femorotibial rollback and rotation was determined. In addition, the native knee joint and different tibial cuts in CR-TKA were compared with Student's t test.

resultsTotal knee replacement with a 3° and 6° varus tibia cut had the greatest varus deviation to the native knee (mean 1.6° ± 0.09°, respectively); while, knees with a 0° (mean 0.2° ± 0.01°) tibia cut were most similar to the constitutional varus knee joint. The femoral roll-back in the medial compartment was increased in the native knee (5.7-12.5 mm). A 6° varus cut had a restricted translation in the medial compartment (2-3.2 mm). In the lateral compartment, the extensive translation was observed with a 0° varus cut, followed by 3° and 6° and the native knee. All cuts showed significantly different mean values. Only the cuts at 3° and at 6° in the medial compartment and the cuts at 0° and at 3° in the lateral compartment did not differ significantly. In respect to tibiofemoral rotation, 0° and 3° varus cuts across all loads had the least difference to the native knee (3.4°), with a 0° varus cut showing a higher absolute internal rotation of the tibia than the native knee. Changes in knee kinematics of the tibiofemoral rotation showed significantly different mean values.

conclusionThe potentially improved outcome parameters in TKA with adapted tibia cuts in constitutional varus knees cannot be completely explained by the changes to knee kinematics. Mechanical alignment seems to result in more balanced load distribution and kinematics more closely resembling the native knee. From a kinematic point of view, it is not recommended to place the tibia in more than 3° of varus. LEVEL OF EVIDENCE: Biomechanical study.

Indexed as

AdultAgedAged, 80 and overArthroplasty, Replacement, KneeBiomechanical PhenomenaCadaverFemaleFemurHumansKnee JointMaleMiddle AgedRange of Motion, ArticularRotationTibiaYoung AdultKneeMechanicsTotal knee replacement

Identifiers

PMID32306132
OpenAlexW3016600760

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked