ArticleMagnetic resonance in medicine2020
Specific absorption rate implications of within-scan patient head motion for ultra-high field MRI.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 24 citations in OpenAlex.
- Using U-Nets to Predict the Effects of Head Motion on Simulated Specific Absorption Rate for Ultra-High Field Magnetic Resonance Imaging With Parallel Transmission.Magnetic resonance in medicine · 2026Article
- MRI and Implant Safety at Low-Field and Ultralow-Field Strengths.Journal of magnetic resonance imaging : JMRI · 2026Review
- Comparison of tight-fitting 7T parallel-transmit head array designs using excitation uniformity and local specific absorption rate metrics.Magnetic resonance in medicine · 2024Article
- Actual patient position versus safety models: Specific Absorption Rate implications of initial head position for Ultrahigh Field Magnetic Resonance Imaging.NMR in biomedicine · 2023Article
- Bench to bore ramifications of inter-subject head differences on RF shimming and specific absorption rates at 7T.Magnetic resonance imaging · 2022Article
- Safety for Human MR Scanners at 7T.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022Article
- Evaluation of specific absorption rate and heating in children exposed to a 7T MRI head coil.Magnetic resonance in medicine · 2022Article
- Correcting inter-scan motion artifacts in quantitative RMagnetic resonance in medicine · 2022Article
- Neuroimaging at 7 Tesla: a pictorial narrative review.Quantitative imaging in medicine and surgery · 2022Review
- Rigid motion-resolvedMagnetic resonance in medicine · 2022Article
- Specific absorption rate and temperature in neonate models resulting from exposure to a 7T head coil.Magnetic resonance in medicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 3 countries.
Funding
Abstract
purposeThis study investigates the implications of all degrees of freedom of within-scan patient head motion on patient safety.
methodsElectromagnetic simulations were performed by displacing and/or rotating a virtual body model inside an 8-channel transmit array to simulate 6 degrees of freedom of motion. Rotations of up to 20° and displacements of up to 20 mm including off-axis axial/coronal translations were investigated, yielding 104 head positions. Quadrature excitation, RF shimming, and multi-spoke parallel-transmit excitation pulses were designed for axial slice-selection at 7T, for seven slices across the head. Variation of whole-head specific absorption rate (SAR) and 10-g averaged local SAR of the designed pulses, as well as the change in the maximum eigenvalue (worst-case pulse) were investigated by comparing off-center positions to the central position.
resultsIn their respective worst-cases, patient motion increased the eigenvalue-based local SAR by 42%, whole-head SAR by 60%, and the 10-g averaged local SAR by 210%. Local SAR was observed to be more sensitive to displacements along right-left and anterior-posterior directions than displacement in the superior-inferior direction and rotation.
conclusionThis is the first study to investigate the effect of all 6 degrees of freedom of motion on safety of practical pulses. Although the results agree with the literature for overlapping cases, the results demonstrate higher increases (up to 3.1-fold) in local SAR for off-axis displacement in the axial plane, which had received less attention in the literature. This increase in local SAR could potentially affect the local SAR compliance of subjects, unless realistic within-scan patient motion is taken into account during pulse design.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.