ReviewMagnetic resonance in medicine2020
Motion correction in magnetic resonance spectroscopy.
Review in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Medial Prefrontal Cortex Glutamate Is Reduced in Schizophrenia and Moderated by Measurement Quality: A Meta-analysis of Proton Magnetic Resonance Spectroscopy Studies.Biological psychiatry · 2021Pooled it
- Does the change in glutamate to GABA ratio correlate with change in depression severity? A randomized, double-blind clinical trial.Molecular psychiatry · 2022Trial
- Improving Fetal Single-Voxel Magnetic Resonance Spectroscopy With Spectral Registration.Magnetic resonance in medicine · 2026Article
- Short Echo-Time Spiral MRSI Versus Single-Voxel Spectroscopy in the Human Brain at 3 Tesla With Semi-LASER Localization.Magnetic resonance in medicine · 2026Article
- Metabolite-Specific Reproducibility of CerebralNMR in biomedicine · 2026Article
- Article
- Fatigue in major depression is linked to depression severity, not sleep duration or anterior cingulate cortex neurochemistry.Journal of affective disorders · 2026Article
- Glutamate, Contextual Insensitivity, and Disorganized Speech in First-Episode Schizophrenia: A 7T Magnetic Resonance Spectroscopy Study.Biological psychiatry global open science · 2025Article
- The Development of Neural Inhibition across Species: Insights from the Hurst Exponent.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2025Article
- Proton Magnetic Resonance Spectroscopy for Pediatric Neuroimaging: Key Concepts for Practice.Seminars in ultrasound, CT, and MR · 2025Review
- Characterising the association between posterior parietal metabolite levels and cortical macrostructure in a cohort spanning childhood to adulthood.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- The developmental trajectory of 1H-MRS brain metabolites from childhood to adulthood.Cerebral cortex (New York, N.Y. : 1991) · 2024Article
- Deuterium body array for the simultaneous measurement of hepatic and renal glucose metabolism and gastric emptying with dynamic 3D deuterium metabolic imaging at 7 T.NMR in biomedicine · 2023Article
- Magnetic resonance imaging of cardiac metabolism in heart failure: how far have we come?European heart journal. Cardiovascular Imaging · 2022Article
- In vivo spectral editing of phosphorylethanolamine.Magnetic resonance in medicine · 2022Article
- Comparison of methods for spectral alignment and signal modelling of GABA-edited MR spectroscopy data.NeuroImage · 2021Article
- Correcting frequency and phase offsets in MRS data using robust spectral registration.NMR in biomedicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In vivo proton magnetic resonance spectroscopy and spectroscopic imaging (MRS/MRSI) are valuable tools to study normal and abnormal human brain physiology. However, they are sensitive to motion, due to strong crusher gradients, long acquisition times, reliance on high magnetic field homogeneity, and particular acquisition methods such as spectral editing. The effects of motion include incorrect spatial localization, phase fluctuations, incoherent averaging, line broadening, and ultimately quantitation errors. Several retrospective methods have been proposed to correct motion-related artifacts. Recent advances in hardware also allow prospective (real-time) correction of the effects of motion, including adjusting voxel location, center frequency, and magnetic field homogeneity. This article reviews prospective and retrospective methods available in the literature and their implications for clinical MRS/MRSI. In combination, these methods can attenuate or eliminate most motion-related artifacts and facilitate the acquisition of high-quality data in the clinical research setting.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials