ArticlePloS one2020
Near-infrared spectroscopy of the placenta for monitoring fetal oxygenation during labour.
Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 16 citations in OpenAlex.
- Digital instrument simulator platform to support the development of noninvasive optical NIR device for placenta monitoring.Journal of biomedical optics · 2026Article
- Placental pathology and its association with duration of abnormal fetal heart tracing in near-term and term infants with hypoxic-ischemic encephalopathy: A retrospective study.Acta obstetricia et gynecologica Scandinavica · 2025Observational
- Correlation of suspicious and pathological cardiotocography with umbilical cord blood gas parameters: A prospective cohort study.Journal of family medicine and primary care · 2025Article
- Finite Element Modeling of Abdominal Near-Infrared Spectroscopy for Infant Splanchnic Oximetry.International journal for numerical methods in biomedical engineering · 2025Article
- A Wireless and Wearable Multimodal Sensor to Non-Invasively Monitor Transabdominal Placental Oxygen Saturation and Maternal Physiological Signals.Biosensors · 2024Article
- Contribution of proactive management of healthcare risks to the reduction of adverse events in a maternity hospital.BMJ open quality · 2024Article
- Evaluation of placental oxygenation by near-infrared spectroscopy in relation to ultrasound maturation grade in physiological term pregnancies.Open medicine (Warsaw, Poland) · 2023Article
- Placental contribution to neonatal encephalopathy.Seminars in fetal & neonatal medicine · 2021Review
- Correction: Near-infrared spectroscopy of the placenta for monitoring fetal oxygenation during labour.PloS one · 2020Article
Corrections and comments
- Erratum issued
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although being the golden standard for intrapartum fetal surveillance, cardiotocography (CTG) has been shown to have poor specificity for detecting fetal acidosis. Non-invasive near-infrared-spectroscopy (NIRS) monitoring of placental oxygenation during labour has not been studied yet. The objective of the study was to determine whether changes in placental NIRS values during labour could identify intrapartum fetal hypoxia and resulting acidosis. We included 43 healthy women in active stage of labour at term. CTG and NIRS parameters in groups with vs. without neonatal umbilical artery pH ≤ 7.20 were compared using Mann-Whitney-U. Receiver-operating-characteristics (ROC) curves were used to estimate predictive value of CTG and NIRS parameters for neonatal pH ≤ 7.20. A computer-based statistical classification was also performed to further evaluate predictive values of CTG and NIRS for neonatal acidosis. Ten (23%) neonates were born with umbilical artery pH ≤ 7.20. Compared to group with pH > 7.20, fetal acidosis was associated with more episodes of placental NIRS deoxygenation (9 (range 2-37) vs. 2 (range 0-65); p<0.001), higher velocity of placental NIRS deoxygenation (2.31 (range 0-22) vs. 1 (range 0-49) %/s; p = 0.03), more decelerations on CTG (25 (range 3-91) vs. 10 (range 10-60); p = 0.02), and more prolonged decelerations on CTG (2 (range 0-4) vs. 1 (range 0-3); p = 0.04). Number of placental deoxygenations had the highest prognostic value for fetal/neonatal acidosis (area under the ROC curve 0.85 (95% confidence interval 0.70-0.99). Computer-based classification also identified number of placental deoxygenations as the most accurate classifier, with 25% false positive and 93% true positive rate in the training dataset, with 100% accuracy when applied to the testing dataset. Placental deoxygenations during labour measured by NIRS are associated with fetal/neonatal acidosis. Predictive value of placental NIRS for neonatal acidosis was superior to that of CTG.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.