Evidence map›Paper›PMID 32293330›Full record

ArticleBMC pregnancy and childbirth2020

Feasibility of non-invasive Foetal electrocardiography in a twin pregnancy.

Lore Noben, Michelle E M H Westerhuis, Judith O E H van Laar, René D Kok, S Guid Oei, Chris H L Peters, Rik Vullings

Open access · goldAbstract read
In one paragraph

Article in BMC pregnancy and childbirth, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Lore NobenDepartment of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands. lore.noben94@gmail.com.
Michelle E M H WesterhuisDepartment of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands.
Judith O E H van LaarDepartment of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands.
René D KokNemo Healthcare BV, 'MMC Incubator', De Run 4630, 5504, DB, Veldhoven, The Netherlands.
S Guid OeiDepartment of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands.
Chris H L PetersDepartment of Clinical Physics, Jeroen Bosch Hospital, P.O. Box 90153, 5200 ME, 's Hertogenbosch, The Netherlands.
Rik VullingsEindhoven MedTech Innovation Centre (e/MTIC), P.O. Box 513, 5600, MB, Eindhoven, The Netherlands.
Máxima Medisch Centrum · NLRadboud University Nijmegen · NLEindhoven University of Technology · NLJeroen Bosch Ziekenhuis · NLNemo Healthcare (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTwin pregnancy is associated with increased perinatal mortality. Close foetal monitoring is therefore warranted. Doppler Ultrasound cardiotocography is currently the only available method to monitor both individual foetuses. Unfortunately, the performance measures of this method are poor and erroneous monitoring of the same twin with both transducers may occur, leaving the second twin unmonitored. In this study we aimed to determine the feasibility of monitoring both foetuses simultaneously in twin gestation by means of non-invasive foetal electrocardiography (NI-fECG), using an electrode patch on the maternal abdomen.

methodsA NI-fECG recording was performed at 25 + 3 weeks of gestation on a multiparous woman pregnant with dichorionic diamniotic twins. An electrode patch consisting of eight adhesive electrodes was applied on the maternal abdomen, yielding six channels of bipolar electrophysiological measurements. The output was digitized and stored for offline processing. The recorded signals were preprocessed by suppression of high-frequency noise, baseline wander, and powerline interference. Secondly, the maternal ECG was subtracted and segmentation into individual ECG complexes was performed. Finally, ensemble averaging of these individual ECG complexes was performed to suppress interferences.

resultsSix different recordings were obtained from each of the six recording channels. Depending on the orientation and distance of the fetal heart with respect to each electrode, a distinction could be made between each fetus based on the morphology of the signals. Yielding of the fetal ECGs was performed manually based on the QRS complexes of each fetus.

conclusionNI-fECG with multiple electrodes allows for monitoring of the fetal heart rate and ECG of both individual fetuses in twin pregnancies.

Indexed as

Heart Rate, FetalPregnancy, TwinAdultElectrocardiographyElectrodesFeasibility StudiesFemaleFetal MonitoringHumansNetherlandsPregnancyPrenatal CareSignal Processing, Computer-AssistedFoetal electrocardiogramFoetal heart rateFoetal monitoringMultiple gestationTwin pregnancy

Identifiers

PMID32293330
PMCPMC7161133
OpenAlexW3015204121

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.