Evidence map›Paper›PMID 32291845›Full record

ArticleMagnetic resonance in medicine2020

Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI.

Matthew C Restivo, Rajiv Ramasawmy, W Patricia Bandettini, Daniel A Herzka, Adrienne E Campbell-Washburn

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed, 1 pooled it
3.1field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

37 citing papers in PubMed, 1 synthesis or guideline pooled it, 49 citations in OpenAlex.

  1. Society for Cardiovascular Magnetic Resonance recommendations toward environmentally sustainable cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Guideline
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Feasibility of fetal cardiac function and anatomy assessment by real-time spiral balanced steady-state free precession magnetic resonance imaging at 0.55T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  15. Review
  16. Measuring biventricular function and left atrial volume in a single five-dimensional whole-heart cardiovascular magnetic resonance scan at 0.55T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  17. Implementation and evaluation of a dynamic contrast-enhanced MR perfusion protocol for glioblastoma using a 0.35 T MRI-Linac system.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2024
    Article
  18. Cardiac MRI at Low Field Strengths.Journal of magnetic resonance imaging : JMRI · 2024
    Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Matthew C RestivoCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland.ORCID 0000-0002-8655-4594
Rajiv RamasawmyCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland.
W Patricia BandettiniCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland.
Daniel A HerzkaCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland.
Adrienne E Campbell-WashburnCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland.ORCID 0000-0002-7169-5693
National Institutes of Health · US

Funding

Diagnostic and interventional cardiovascular catheterizationZIDHL006061 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2010 to 2025
$18.2M
Gadgetron Global Network and Intelligence Computing: Clinical Imaging Application Development and Software InfrastructureZIAHL006214 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI KELLMAN, PETER · 2016 to 2025
$7.3M
Innovative Technology for MRI Guided ProceduresZIAHL006213 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2016 to 2025
$5.4M
Intramural NIH HHS ZIA HL006213Intramural NIH HHS ZIA HL006214
6 · The paper itself

Abstract

purposeLow-field MRI offers favorable physical properties for SNR-efficient long readout acquisitions such as spiral and EPI. We used a 0.55 tesla (T) MRI system equipped with high-performance hardware to increase the sampling duty cycle and extend the TR of balanced steady-state free precession (bSSFP) cardiac cine acquisitions, which typically are limited by banding artifacts.

methodsWe developed a high-efficiency spiral in-out bSSFP acquisition, with zeroth- and first-gradient moment nulling, and an EPI bSSFP acquisition for cardiac cine imaging using a contemporary MRI system modified to operate at 0.55T. Spiral in-out and EPI bSSFP cine protocols, with TR = 8 ms, were designed to maintain both spatiotemporal resolution and breath-hold length. Simulations, phantom imaging, and healthy volunteer imaging studies (n = 12) were performed to assess SNR and image quality using these high sampling duty-cycle bSSFP sequences.

resultsSpiral in-out bSSFP performed favorably at 0.55T and generated good image quality, whereas EPI bSSFP suffered motion and flow artifacts. There was no difference in ejection fraction comparing spiral in-out with standard Cartesian imaging. Moreover, human images demonstrated a 79% ± 21% increase in myocardial SNR using spiral in-out bSSFP and 50% ± 14% increase in SNR using EPI bSSFP as compared with the reference Cartesian acquisition. Spiral in-out acquisitions at 0.55T recovered 69% ± 14% of the myocardial SNR at 1.5T.

conclusionEfficient bSSFP spiral in-out provided high-quality cardiac cine imaging and SNR recovery on a high-performance 0.55T MRI system.

Indexed as

Image Interpretation, Computer-AssistedMagnetic Resonance ImagingArtifactsBreath HoldingHeartHumansMagnetic Resonance Imaging, CinebSSFPcardiac cineEPIlow fieldspiral in-out

Identifiers

PMID32291845
PMCPMC7402011
OpenAlexW3016167188

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked