Evidence map›Paper›PMID 32291530›Full record

ArticleSurgical case reports2020

Magnetic compression anastomosis with atypical anastomosis for anastomotic stenosis of the sigmoid colon: a case report.

Teppei Kamada, Hironori Ohdaira, Sojun Hoshimoto, Satoshi Narihiro, Norihiko Suzuki, Rui Marukuchi, Hideyuki Takeuchi, Masashi Yoshida, Eigoro Yamanouchi, Yutaka Suzuki

Open access · goldAbstract read
In one paragraph

Article in Surgical case reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Teppei KamadaDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan. teppei0911show@yahoo.co.jp.
Hironori OhdairaDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Sojun HoshimotoDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Satoshi NarihiroDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Norihiko SuzukiDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Rui MarukuchiDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Hideyuki TakeuchiDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Masashi YoshidaDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Eigoro YamanouchiDepartment of Radiology, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
Yutaka SuzukiDepartment of Surgery, International University of Health and Welfare Hospital, 537-3, Iguchi, Nasushiobara, Tochigi, 329-2763, Japan.
International University of Health and Welfare · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMagnetic compression anastomosis (MCA) is mainly applied in the gastrointestinal and biliary tracts through a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. Magnets usually adsorb in the end-to-end direction (end-to-end anastomosis), exert a strong magnetic force and create an anastomosis according to the size of the magnets. Regular endoscopic dilation is required to prevent restenosis when the anastomotic size is small. We report a case in which MCA was successfully used to treat anastomotic stenosis of the sigmoid colon; the magnets adsorbed in the side-to-side direction rather than the end-to-end direction and generated a wide anastomosis in a short time that did not require endoscopic dilation. CASE PRESENTATION: An 81-year-old woman was admitted to our hospital to treat anastomotic stenosis of the sigmoid colon for closure of transverse colostomy. Two years prior, the Hartmann operation and drainage were performed at other hospitals due to perforated diverticulitis of the sigmoid colon. Obstruction of the sigmoid colostomy occurred, and a transverse colostomy was performed. One year after the first surgery, high anterior resection was performed, but anastomotic stenosis occurred, causing obstruction. MCA was planned because the patient had a history of multiple operations and was expected to have strong adhesions postoperatively. MCA was safely performed, but two magnets were accidently adsorbed in the side-to-side direction. The magnet position could not be changed. The two magnets were expected to move and adsorb in an end-to-end direction naturally due to bowel movements. The magnets that adsorbed in the side-to-side direction dropped from the anus 5 days after treatment, and the anastomosis was observed by colonoscopy. Three ileus tubes were placed from the transverse colostomy beyond the anastomosis to prevent restenosis. Colonoscopy showed that the anastomosis diameter was wider than expected at 14 days after treatment, and endoscopic dilation was not necessary. No complications were observed in this patient's postoperative course. Finally, closure of the patient's colostomy was successfully performed.

conclusionsMCA with side-to-side anastomosis generated a wide anastomosis in a short time.

Indexed as

Magnetic compression anastomosisSide-to-side anastomosis

Identifiers

PMID32291530
PMCPMC7156530
OpenAlexW3023842223

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.