Evidence map›Paper›PMID 32290176›Full record

ArticleMicromachines2020

Standing Air Bubble-Based Micro-Hydraulic Capacitors for Flow Stabilization in Syringe Pump-Driven Systems.

Yidi Zhou, Jixiao Liu, Junjia Yan, Tong Zhu, Shijie Guo, Songjing Li, Tiejun Li

Abstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Periodic Flows in Microfluidics.Small (Weinheim an der Bergstrasse, Germany) · 2024
    Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Capillaric field effect transistors.Microsystems & nanoengineering · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yidi ZhouSchool of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China.ORCID 0000-0002-6090-5536
Jixiao LiuSchool of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China.
Junjia YanSchool of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China.
Tong ZhuSchool of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China.
Shijie GuoSchool of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China.
Songjing LiSchool of Mechatronics, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-7488-8087
Tiejun LiSchool of Mechanical Engineering, Hebei University of Technology, Tianjin 300132, China.

Funding

National Natural Science Foundation of China 51505123National Natural Science Foundation of China 51605136Natural Science Foundation of Hebei Province E2015202194Natural Science Foundation of Hebei Province E2017202248Postdoctoral Research Foundation of China 2016M600180
6 · The paper itself

Abstract

Unstable liquid flow in syringe pump-driven systems due to the low-speed vibration of the step motor is commonly observed as an unfavorable phenomenon, especially when the flow rate is relatively small. Upon the design of a convenient and cost-efficient microfluidic standing air bubble system, this paper studies the physical principles behind the flow stabilization phenomenon of the bubble-based hydraulic capacitors. A bubble-based hydraulic capacitor consists of three parts: tunable microfluidic standing air bubbles in specially designed crevices on the fluidic channel wall, a proximal pneumatic channel, and porous barriers between them. Micro-bubbles formed in the crevices during liquid flow and the volume of the bubble can be actively controlled by the pneumatic pressure changing in the proximal channel. When there is a flowrate fluctuation from the upstream, the flexible air-liquid interface would deform under the pressure variation, which is analogous to the capacitive charging/discharging process. The theoretical model based on Euler law and the microfluidic equivalent circuit was developed to understand the multiphysical phenomenon. Experimental data characterize the liquid flow stabilization performance of the flow stabilizer with multiple key parameters, such as the number and the size of microbubbles. The developed bubble-based hydraulic capacitor could minimize the flow pulses from syringe pumping by 75.3%. Furthermore, a portable system is demonstrated and compared with a commercial pressure-driven flow system. This study can enhance the understanding of the bubble-based hydraulic capacitors that would be beneficial in microfluidic systems where the precise and stable liquid flow is required.

Indexed as

bubble-basedexperimental studiesflow regulationfluidic capacitorstheoretical model

Identifiers

PMID32290176
PMCPMC7231304

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked