ArticleInformatics in medicine unlocked2019
A non-contact infection screening system using medical radar and Linux-embedded FPGA: Implementation and preliminary validation.
Article in Informatics in medicine unlocked, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.
- Systematic Literature Review Regarding Heart Rate and Respiratory Rate Measurement by Means of Radar Technology.Sensors (Basel, Switzerland) · 2024Pooled it
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesIn this study, an infection screening system was developed to detect patients suffering from infectious diseases. In addition, the system was also designed to deal with the variability in age and gender, which would affect the accuracy of the detection. Furthermore, to enable a low-cost, non-contact and embedded system, multiple vital signs from a medical radar were measured and all algorithms were implemented on a Field Programmable Gate Array, named PYNQ-Z1.
methodsThe system consisted of two main stages: digital signal processing and data classification. In the former stage, Butterworth filters, with flexible cut-off frequencies depending on age and gender, and a time-domain peak detection algorithm were deployed to compute three vital signs, namely heart rate, respiratory rate, and standard deviation of heart beat-to-beat interval. For the classification problem, two machine learning models, Support Vector Machine and Quadratic Discriminant Analysis, were implemented.
resultsThe Student's
conclusionThis study outlines the implementation of an infection screening system, which achieved competent performance. The system might be beneficial for fast screening of infected patients at public health centers in underdeveloped areas, where people have little access to healthcare.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.