Evidence map›Paper›PMID 32288118›Full record

ArticleEnergy and buildings2017

Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation.

Jihong Wang, Tengfei Zhang, Shugang Wang, Francine Battaglia

Abstract read
In one paragraph

Article in Energy and buildings, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jihong WangSchool of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian 116024, China.
Tengfei ZhangSchool of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian 116024, China.
Shugang WangSchool of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian 116024, China.
Francine BattagliaDepartment of Mechanical Engineering, Virginia Polytechnic Institute and State University, 635 Prices Fork Road, Blacksburg, VA 24061, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Natural ventilation is an effective strategy to control thermal comfort in buildings, and can be enhanced depending on the window style. The combination of natural ventilation and window can also facilitate the removal or dilution of gaseous pollutants from indoor sources in newly decorated buildings. However, the windows on the same facade may cause gaseous pollutant cross-transmission during single-sided natural ventilation between households on different floors close to the source. Although some research has focused on the pollutant cross-transmission in buildings, the simplification of windows into rectangular openings often affects accurate knowledge of pollutant transmission characteristics. Therefore, this investigation explored gaseous pollutant cross-transmission through real windows during single-sided, buoyancy-driven ventilation in a multistory building. Six types of windows were modeled for the indoor pollutant of gaseous formaldehyde (HCHO). Computational fluid dynamics (CFD) was utilized to solve characteristics of pollutant transmission inside and outside the multistory building. The results indicated that the ventilation rates, thermal profiles and pollutant transmission inside and outside the building varied for each window type, although the open window areas were identical. The re-entry ratio of exhausted air entering upper floors and the infection risk of epidemic viruses caused by airborne cross-transmission was sensitive to ventilation rates and window configurations, while the sensitivities for window configurations varied case by case. The comparisons also revealed that the specification of ambient temperature and pollutant release rate ultimately did not affect the evaluation of pollutant cross-transmission using CFD.

Indexed as

CFDCross-transmissionGaseous pollutantNatural ventilationWindow configuration

Identifiers

PMID32288118
PMCPMC7127727

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.