Evidence map›Paper›PMID 32287815›Full record

ArticleMeasurement : journal of the International Measurement Confederation2020

Towards health monitoring using remote heart rate measurement using digital camera: A feasibility study.

M A Hassan, A S Malik, D Fofi, B Karasfi, F Meriaudeau

Abstract read
In one paragraph

Article in Measurement : journal of the International Measurement Confederation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

M A HassanElectrical and Computer Engineering, The University of Alabama, SERC 3060, Tuscaloosa, AL 35487, USA.
A S MalikCentre for Intelligent Signal and Imaging Research (CISIR), Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak, Malaysia.
D FofiLe2i UMR 6306, CNRS, Arts et Métiers, Univ. Bourgogne Franche-Comté 12, rue de la fonderie, 71200 Le Creusot, France.
B KarasfiCentre for Intelligent Signal and Imaging Research (CISIR), Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610 Bandar Seri Iskandar, Perak, Malaysia.
F MeriaudeauLe2i UMR 6306, CNRS, Arts et Métiers, Univ. Bourgogne Franche-Comté 12, rue de la fonderie, 71200 Le Creusot, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The paper presents a feasibility study for heart rate measurement using a digital camera to perform health monitoring. The feasibility study investigates the reliability of the state of the art heart rate measuring methods in realistic situations. Therefore, an experiment was designed and carried out on 45 subjects to investigate the effects caused by illumination, motion, skin tone, and distance variance. The experiment was conducted for two main scenarios; human-computer interaction scenario and health monitoring scenario. The human-computer scenario investigated the effects caused by illumination variance, motion variance, and skin tone variance. The health monitoring scenario investigates the feasibility of health monitoring at public spaces (i.e. airports, subways, malls). Five state of the art heart rate measuring methods were re-implemented and tested with the feasibility study database. The results were compared with ground truth to estimate the heart rate measurement error. The heart rate measurement error was analyzed using mean error, standard deviation; root means square error and Pearson correlation coefficient. The findings of this experiment inferred promising results for health monitoring of subjects standing at a distance of 500 cm.

Indexed as

BallistocardiographyFacial ImagingHeart rate measurementNon-contactPhotoplethysmography

Identifiers

PMID32287815
PMCPMC7126755

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.