Evidence map›Paper›PMID 32287531›Full record

ReviewTrends in analytical chemistry : TRAC2019

LAMP-on-a-chip: Revising microfluidic platforms for loop-mediated DNA amplification.

Haoqing Zhang, Ying Xu, Zdenka Fohlerova, Honglong Chang, Ciprian Iliescu, Pavel Neuzil

Abstract readReview
In one paragraph

Review in Trends in analytical chemistry : TRAC, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 87 papers.

0numbers the graph read from it
0cells of the map it votes in
87citing papers in PubMed
11.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

87 citing papers in PubMed, 218 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
  18. Review
  19. Article
  20. Review

27 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Haoqing ZhangNorthwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.
Ying XuNorthwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.
Zdenka FohlerovaCentral European Institute of Technology, Brno University of Technology, Purkyňova 123, 61300 Brno, Czech Republic.
Honglong ChangNorthwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.
Ciprian IliescuBiomedical Institute for Global Health Research and Technology (BIGHEART), National University of Singapore, MD6, 14 Medical Drive #14-01, 117599, Singapore.
Pavel NeuzilNorthwestern Polytechnical University, School of Mechanical Engineering, Department of Microsystem Engineering, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.
Northwestern Polytechnical University · CNCentral European Institute of Technology · CZNational University of Singapore · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Nucleic acid amplification for the detection of infectious diseases, food pathogens, or assessment of genetic disorders require a laboratory setting with specialized equipment and technical expertise. Isothermal deoxyribonucleic acid amplification methods, such as loop-mediated isothermal amplification (LAMP), exhibit characteristics ideal for point-of-care (POC) applications, since their instrumentation is simpler in comparison with the standard method of polymerase chain reaction. Other key advantages of LAMP are robustness and the production of pyrophosphate in the presence of the target gene, enabling to detect the reaction products using the naked eye. Polymerase inhibitors, presented in clinical samples, do not affect the amplification process, making LAMP suitable for a simple sample-to-answer diagnostic systems with simplified sample preparation. In this review, we discuss the trends in miniaturized LAMP techniques, such as microfluidic, paper-based, and digital with their advantages and disadvantages, especially for POC applications alongside our opinion of the future development of miniaturized LAMP.

Indexed as

Digital LAMPLAMPMicrofluidicMulti gene detectionPaper-based LAMPPCRPOCSingle gene detection

Identifiers

PMID32287531
PMCPMC7112807
OpenAlexW2911715832

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.