Evidence map›Paper›PMID 32286403›Full record

ArticleScientific reports2020

A Quantitative Comparison of the Counting Significance of van Hove Integral Spectroscopy and Quasielastic Neutron Scattering.

Antonio Benedetto, Gordon J Kearley

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Antonio BenedettoSchool of Physics, University College Dublin, Dublin 4, Ireland. antonio.benedetto@ucd.ie.
Gordon J KearleySchool of Physics, University College Dublin, Dublin 4, Ireland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have recently proposed a new method to access system dynamics via neutron scattering based on measuring the elastic scattered intensity: By varying the energy band-width that impinges on the sample (also known as instrumental energy resolution), the purely elastic-scattering from this variation is the running time-integral of the intermediate scattering function (I(t)) [Benedetto and Kearley, Sci. Rep. 9, 11284, 2019]. In this correspondence we denote our method "vHI", which stands for "van Hove Integral". The method is now widely accepted as "valid" and here we focus on the efficiency of the vHI method compared with the standard quasi-elastic neutron scattering (QENS) method. We use a numerical Monte-Carlo simulation of an instrument that is equally capable of measuring QENS and vHI under identical conditions. For an "experiment" in which the same number of neutrons enter the instrument, we present comparisons between QENS and vHI at three levels of data-reduction. Firstly, at the raw-data level vHI achieves 100 times more neutrons at the detector than QENS. Secondly, vHI has a factor of 2 less statistical error, which would translate to an overall gain of 4 for vHI in counting-time. Lastly, we compare the distortions caused in obtaining the final I(t) via time-Fourier transform (QENS) and polynomial time-derivative (vHI). Here, the statistical error is 10 times smaller for vHI. This last comparison is the most important result where the 10 times smaller residual for vHI gives a net gain in counting time of 100 better than QENS to obtain the same underlying dynamics of the system under study.

Identifiers

PMID32286403
PMCPMC7156666

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.