ArticleScientific reports2020
A Quantitative Comparison of the Counting Significance of van Hove Integral Spectroscopy and Quasielastic Neutron Scattering.
Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Microscopic versus Macroscopic Glass Transitions and Relevant Length Scales in Mixtures of Industrial Interest.Macromolecules · 2023Article
- Experimental demonstration of the novel "van-Hove integral method (vHI)" for measuring diffusive dynamics by elastic neutron scattering.Scientific reports · 2021Article
- From protein and its hydration water dynamics to controlling mechano-elasticity of cellular lipid membranes and cell migration via ionic liquids.Biophysical reviews · 2020Article
- From just physics to biophysics of biological systems.Biophysical reviews · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We have recently proposed a new method to access system dynamics via neutron scattering based on measuring the elastic scattered intensity: By varying the energy band-width that impinges on the sample (also known as instrumental energy resolution), the purely elastic-scattering from this variation is the running time-integral of the intermediate scattering function (I(t)) [Benedetto and Kearley, Sci. Rep. 9, 11284, 2019]. In this correspondence we denote our method "vHI", which stands for "van Hove Integral". The method is now widely accepted as "valid" and here we focus on the efficiency of the vHI method compared with the standard quasi-elastic neutron scattering (QENS) method. We use a numerical Monte-Carlo simulation of an instrument that is equally capable of measuring QENS and vHI under identical conditions. For an "experiment" in which the same number of neutrons enter the instrument, we present comparisons between QENS and vHI at three levels of data-reduction. Firstly, at the raw-data level vHI achieves 100 times more neutrons at the detector than QENS. Secondly, vHI has a factor of 2 less statistical error, which would translate to an overall gain of 4 for vHI in counting-time. Lastly, we compare the distortions caused in obtaining the final I(t) via time-Fourier transform (QENS) and polynomial time-derivative (vHI). Here, the statistical error is 10 times smaller for vHI. This last comparison is the most important result where the 10 times smaller residual for vHI gives a net gain in counting time of 100 better than QENS to obtain the same underlying dynamics of the system under study.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.