Lead one ratio in left bundle branch block predicts poor cardiac resynchronization therapy response.

Zak Loring, Daniel J Friedman, Kasper Emerek, Claus Graff, Peter L Sørensen, Steen M Hansen, Bjorn Wieslander, Martin Ugander, Peter Søgaard, Brett D Atwater

Open access · bronzeAbstract read
In one paragraph

Article in Pacing and clinical electrophysiology : PACE, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 3 countries.

Zak LoringDivision of Cardiology, Department of Medicine, Duke University Medical Center, Durham, North Carolina.ORCID 0000-0002-4613-582X
Daniel J FriedmanDivision of Cardiology, Department of Medicine, Duke University Medical Center, Durham, North Carolina.
Kasper EmerekDivision of Cardiology, Department of Medicine, Duke University Medical Center, Durham, North Carolina.
Claus GraffDepartment of Health Science and Technology, Aalborg University, Aalborg, Denmark.
Peter L SørensenDepartment of Health Science and Technology, Aalborg University, Aalborg, Denmark.
Steen M HansenUnit of Epidemiology and Biostatistics, Aalborg University Hospital, Aalborg, Denmark.
Bjorn WieslanderDepartment of Clinical Physiology, Karolinska Institute, and Karolinska University Hospital, Stockholm, Sweden.
Martin UganderDepartment of Clinical Physiology, Karolinska Institute, and Karolinska University Hospital, Stockholm, Sweden.
Peter SøgaardDepartment of Clinical Medicine, Aalborg University, Aalborg, Denmark.
Brett D AtwaterDivision of Cardiology, Department of Medicine, Duke University Medical Center, Durham, North Carolina.ORCID 0000-0002-0468-3668
Aalborg University · DKClinical Research Institute · USDuke Medical Center · USKarolinska University Hospital · SEAalborg University Hospital · DK

Funding

Postdoctoral Training in Cardiovascular Clinical ResearchT32HL069749 · NHLBI · DUKE UNIVERSITY · PI MARK, DANIEL B · 2003 to 2023
$6.7M
NHLBI NIH HHS T32 HL069749NIH HHS 5T32HL069749
6 · The paper itself

Abstract

backgroundA low electrocardiogram (ECG) lead one ratio (LOR) of the maximum positive/negative QRS amplitudes is associated with lower left ventricular ejection fraction (LVEF) and worse outcomes in left bundle branch block (LBBB); however, the impact of LOR on cardiac resynchronization therapy (CRT) outcomes is unknown. We compared clinical outcomes and echocardiographic changes after CRT implantation by LOR.

methodsConsecutive CRT-defibrillator recipients with LBBB implanted between 2006 and 2015 at Duke University Medical Center were included (N = 496). Time to heart transplant, left ventricular assist device (LVAD) implantation, or death was compared among patients with LOR <12 vs ≥12 using Cox-proportional hazard models. Changes in LVEF and LV volumes after CRT were compared by LOR.

resultsBaseline ECG LOR <12 was associated with an adjusted hazard ratio (HR) of 1.69 (95% CI: 1.12-2.40, P = .01) for heart transplant, LVAD, or death. Patients with LOR <12 had less reduction of LV end diastolic volume (ΔLVEDV -4 ± 21 vs -13 ± 23%, P = .04) and LV end systolic volume (ΔLVESV -9 ± 27 vs -22 ± 26%, P = .03) after CRT. In patients with QRS duration (QRSd) ≥150 ms, LOR <12 was associated with an adjusted HR of 2.01 (95% CI 1.21-3.35, P = .008) for heart transplant, LVAD, or death, compared with LOR ≥12.

conclusionsBaseline ECG LOR <12 portends worse outcomes after CRT implantation in patients with LBBB, specifically among those with QRSd ≥150 ms. This ECG ratio may identify patients with a class I indication for CRT implantation at high risk for poor postimplantation outcomes.

Indexed as

Cardiac Resynchronization TherapyElectrodes, ImplantedAgedBundle-Branch BlockEchocardiographyElectrocardiographyFemaleHeart-Assist DevicesHeart TransplantationHumansMaleMiddle AgedStroke Volumecardiac resynchronization therapyclinical outcomesechocardiographyelectrocardiographyleft bundle branch block

Identifiers

PMID32285950
PMCPMC7324940
OpenAlexW3016169878

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.