Evidence map›Paper›PMID 32284498›Full record

ArticleMicromachines2020

Sensitivity Comparison of Refractive Index Transducer Optical Fiber Based on Surface Plasmon Resonance Using Ag, Cu, and Bimetallic Ag-Cu Layer.

Rozalina Zakaria, Nur Aina'a Mardhiah Zainuddin, Sofiah Athirah Raya, Siti Anis Khairani Alwi, Toni Anwar, Aliza Sarlan, Kawsar Ahmed, Iraj Sadegh Amiri

Abstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Advances in Plasmonic Sensing at the NIR-A Review.Sensors (Basel, Switzerland) · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rozalina ZakariaPhotonics Research Centre, Faculty of Science, University of Malaya, Kuala Lumpur 50603, Malaysia.ORCID 0000-0002-6445-3039
Nur Aina'a Mardhiah ZainuddinPhotonics Research Centre, Faculty of Science, University of Malaya, Kuala Lumpur 50603, Malaysia.
Sofiah Athirah RayaPhotonics Research Centre, Faculty of Science, University of Malaya, Kuala Lumpur 50603, Malaysia.
Siti Anis Khairani AlwiPhotonics Research Centre, Faculty of Science, University of Malaya, Kuala Lumpur 50603, Malaysia.
Toni AnwarDepartment of Computer and Information Science (DCIS), Faculty of Science and Information Technology (FSIT), Universiti Teknologi Petronas (UTP), Seri Iskandar 32610, Malaysia.
Aliza SarlanDepartment of Computer and Information Science (DCIS), Faculty of Science and Information Technology (FSIT), Universiti Teknologi Petronas (UTP), Seri Iskandar 32610, Malaysia.
Kawsar AhmedDepartment of Information and Communication Technology, Mawlana Bhashani Science and Technology University, Santosh, Tangail 1902, Bangladesh.ORCID 0000-0002-4034-9819
Iraj Sadegh AmiriComputational Optics Research Group, Advanced Institute of Materials Science, Ton Duc Thang University, Ho Chi Minh City 700000, Vietnam.

Funding

UNIVERSITY MALAYA FP034-2017A
6 · The paper itself

Abstract

A single-mode optical fiber sensor uses surface plasmon resonance (SPR) with a bimetallic silver-copper (Ag-Cu) coating compared to a single layer of Ag and Cu itself. Bimetallic Ag-Cu sensors are constructed by simple fabrication on a side-polished optical fiber, followed by an electron beam evaporation of Ag and Cu films. For this investigation, the thickness of the single Ag layer was set to 30 nm and the single Cu layer was set to 30 nm; whereas for the bimetallic combined Ag-Cu layer the thickness of Ag was 7 nm and Cu 23 nm. The sensor performance was analyzed and compared experimentally and numerically using the COMSOL Multiphysics. A white light source was used with a broad optical bandwidth to provide a range of wavelengths to the optical fiber. The characteristics of the thin layers of Ag, Cu, and Ag-Cu as alcohol sensors were evaluated. We found that Cu was the most sensitive metallic layer compared to the Ag and the bimetallic Ag-Cu layers. For a 100% alcohol concentration, Cu showed a sensitivity of 425 nm/RIU followed by the bimetallic Ag-Cu layer with 108.33 nm/RIU, whereas the Ag layer was not detected. Interestingly, sensitivity reached saturation beyond the 20 nm thick layer of Ag. This shows that the Cu and the bimetallic Ag-Cu layers are suitable for an alcohol-based optical sensor.

Indexed as

alcohol sensorbimetallic layerD-shaped optical fiberSPR

Identifiers

PMID32284498
PMCPMC7019253

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.