Evidence map›Paper›PMID 32283745›Full record

ArticleMaterials (Basel, Switzerland)2020

Electrochemical and Biological Performance of Biodegradable Polymer Coatings on Ti6Al7Nb Alloy.

Wojciech Kajzer, Janusz Szewczenko, Anita Kajzer, Marcin Basiaga, Marcin Kaczmarek, Magdalena Antonowicz, Joanna Jaworska, Katarzyna Jelonek, Arkadiusz Orchel, Katarzyna Nowińska and 1 more

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Wojciech KajzerDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland.ORCID 0000-0001-9285-1272
Janusz SzewczenkoDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland.
Anita KajzerDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland.
Marcin BasiagaDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland.
Marcin KaczmarekDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland.
Magdalena AntonowiczDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland.
Joanna JaworskaCentre of Polymer and Carbon Materials of the Polish Academy of Sciences, 41-819 Zabrze, Poland.
Katarzyna JelonekCentre of Polymer and Carbon Materials of the Polish Academy of Sciences, 41-819 Zabrze, Poland.ORCID 0000-0003-2625-5434
Arkadiusz OrchelDepartment of Biopharmacy, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, 40-055 Katowice, Poland.ORCID 0000-0001-7826-0759
Katarzyna NowińskaFaculty of Mining and Geology, Department of Applied Geology, Silesian University of Technology, 44-100 Gliwice, Poland.
Janusz KasperczykCentre of Polymer and Carbon Materials of the Polish Academy of Sciences, 41-819 Zabrze, Poland.ORCID 0000-0002-8943-9508
Silesian University of Technology · PLCentre of Polymer and Carbon Materials · PLMedical University of Silesia · PL

Funding

Narodowe Centrum Nauki 2015/19/B/ST5/03431
6 · The paper itself

Abstract

The inhibition of the corrosion of metal implants is still a challenge. This study aimed to increase the corrosion resistance of Ti6Al7Nb alloy implants through surface modification, including grinding, sandblasting, and anodic oxidation followed by the deposition of a polymer coating. The aim of the work was to determine the influence of biodegradable polymer coatings on the physico-chemical properties of a Ti6Al7Nb alloy used for short-term implants. Biodegradable coatings prepared from poly(glycolide-caprolactone) (P(GCap)), poly(glycolide ε-caprolactone-lactide) (P(GCapL)), and poly(lactide-glycolide) (PLGA) were applied in the studies. The dip-coating method with three cycles of dipping was applied. Corrosion resistance was assessed on the basis of potentiodynamic studies. The studies were carried out on samples after 30, 60, and 90 days of exposure to Ringer's solution. Surface topography, wettability, and cytotoxicity studies were also carried out. The degradation process of the base material was evaluated on the basis of the mass density of the metal ions released to the solution. The results indicated the influence of the coating type on corrosion resistance. In addition, a beneficial effect of the polymer coating on the reduction of the density of the released metal ions was found, as compared to the samples without polymer coatings. The obtained results provide basic knowledge for the development of polymer coatings enriched with an active substance. The presence of ciprofloxacin in the coating did not reduce the corrosion resistance of the metal substrate. Moreover, the cytotoxicity test using the extract dilution method demonstrated that the implants' coatings are promising for further in vitro and in vivo studies.

Indexed as

corrosion resistancecytotoxicitydrug-eluting polymer coatingsmetallic ion releaseTi6Al7Nbwettability

Identifiers

PMID32283745
PMCPMC7178650
OpenAlexW3016030521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.