Evidence map›Paper›PMID 32279202›Full record

ArticleMedical & biological engineering & computing2020

The implications of non-anatomical positioning of a meniscus prosthesis on predicted human knee joint biomechanics.

Hamid Naghibi, Dennis Janssen, Ton van den Boogaard, Tony van Tienen, Nico Verdonschot

Open access · hybridAbstract read
In one paragraph

Article in Medical & biological engineering & computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Hamid NaghibiRobotics and Mechatronics Lab, Technical Medical (TechMed) Centre, University of Twente, Building Carré, Room CR 3607, P.O. Box 217, 7500 AE, Enschede, The Netherlands. Hamid.naghibi.190@gmail.com.
Dennis JanssenRadboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands.
Ton van den BoogaardNonlinear Solid Mechanics, Faculty of Engineering Technology, University of Twente, 7522 NB, Enschede, The Netherlands.
Tony van TienenRadboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands.
Nico VerdonschotRadboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands.
Radboud University Medical Center · NLUniversity of Twente · NLUniversity Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Despite all the efforts to optimize the meniscus prosthesis system (geometry, material, and fixation type), the success of the prosthesis in clinical practice will depend on surgical factors such as intra-operative positioning of the prosthesis. In this study, the aim was therefore to assess the implications of positional changes of the medial meniscus prosthesis for knee biomechanics. A detailed validated finite element (FE) model of human intact and meniscal implanted knees was developed based on a series of in vitro experiments. Different non-anatomical prosthesis positions were applied in the FE model, and the biomechanical response during the gait stance phase compared with an anatomically positioned prosthesis, as well as meniscectomized and also the intact knee model. The results showed that an anatomical positioning of the medial meniscus prosthesis could better recover the intact knee biomechanics, while a non-anatomical positioning of the prosthesis to a limited extent alters the knee kinematics and articular contact pressure and increases the implantation failure risk. The outcomes indicate that a medial or anterior positioning of the meniscus prosthesis may be more forgiving than a posteriorly or laterally positioned prosthesis. The outcome of this study may provide a better insight into the possible consequences of meniscus prosthesis positioning errors for the patient and the prosthesis functionality. Graphical abstract.

Indexed as

Knee ProsthesisArthroplasty, ReplacementBiomechanical PhenomenaCadaverEquipment DesignFinite Element AnalysisGaitHumansKnee JointMenisci, TibialModels, AnatomicReproducibility of ResultsStress, MechanicalTibial Meniscus InjuriesFinite element analysisGait simulationImplant positioningMeniscus injuryMeniscus prosthesisOsteoarthritis risk

Identifiers

PMID32279202
PMCPMC7211793
OpenAlexW3015690021

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.