Evidence map›Paper›PMID 32277741›Full record

ArticleJournal of applied clinical medical physics2020

The effect of stereotactic body radiotherapy (SBRT) using flattening filter-free beams on cardiac implantable electronic devices (CIEDs) in clinical situations.

Hossein Aslian, Tomas Kron, Troy Watts, Cagla Akalanli, Nicholas Hardcastle, Peta Lonski, Atousa Montaseri, Barry Hay, James Korte, Kemal Berk and 2 more

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Radiation therapy for ventricular arrhythmias.Journal of medical imaging and radiation oncology · 2024
    Review
  7. Review
  8. Local dose rate effects in implantable cardioverter-defibrillators with flattening filter free and flattened photon radiation.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022
    Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 5 institutions in 2 countries.

Hossein AslianDepartment of Physics, University of Trieste, Trieste, Italy.
Tomas KronPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Troy WattsDepartment of Cardiology, Royal Melbourne Hospital, Melbourne, Australia.
Cagla AkalanliPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Nicholas HardcastlePhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Peta LonskiPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Atousa MontaseriPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Barry HayPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
James KortePhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Kemal BerkPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.
Francesco LongoDepartment of Physics, University of Trieste, Trieste, Italy.
Mara SevergniniDepartment of Medical Physics, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy.
Peter MacCallum Cancer Centre · AUAzienda Sanitaria Universitaria Integrata di Trieste · ITIstituto Nazionale di Fisica Nucleare, Sezione di Trieste · ITThe Royal Melbourne Hospital · AUUniversity of Trieste · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study focused on determining risks from stereotactic radiotherapy using flattening filter-free (FFF) beams for patients with cardiac implantable electronic device (CIEDs). Two strategies were employed: a) a retrospective analysis of patients with CIEDs who underwent stereotactic radiosurgery (SRS)/SBRT at the Peter MacCallum Cancer Centre between 2014 and 2018 and b) an experimental study on the impact of FFF beams on CIEDs.

methodsA retrospective review was performed. Subsequently, a phantom study was performed using 30 fully functional explanted CIEDs from two different manufacturers. Irradiation was carried out in a slab phantom with 6-MV and 10-MV FFF beams. First, a repetition-rate test (RRT) with a range of beam pulse frequencies was conducted. Then, multifraction SBRT (48 Gy/4 Fx) and single-fraction SBRT (28 Gy/1 Fx) treatment plans were used for lung tumors delivered to the phantom.

resultsBetween 2014 and 2018, 13 cases were treated with an FFF beam (6 MV, 1400 MU/min or 10 MV, 2400 MU/min), and 15 cases were treated with a flattening filter (FF) beam (6 MV, 600 MU/min). All the devices were positioned outside the treatment field at a distance of more than 5 cm, except for one case, and no failures were reported due to SBRT/SRS. In the phantom rep-rate tests, inappropriate sensing occurred, starting at a rep-rate of 1200 MU/min. Cardiac implantable electronic device anomalies during and after delivering VMAT-SBRT with a 10-MV FFF beam were observed.

conclusionsThe study showed that caution should be paid to managing CIED patients when they undergo SBRT using FFF beams, as it is recommended by AAPM TG-203. Correspondingly, it was found that for FFF beams although there is small risk from dose-rate effects, delivering high dose of radiation with beam energy greater than 6 MV and high-dose rate to CIEDs positioned in close vicinity of the PTV may present issues.

Indexed as

RadiosurgeryRadiotherapy, Intensity-ModulatedElectronicsHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective Studiescardiac implantable electronic device (CIED)flattening filter-free (FFF) beamsstereotactic body radiotherapy (SBRT)volumetric-modulated arc therapy (VMAT)

Identifiers

PMID32277741
PMCPMC7324704
OpenAlexW3016076944

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.