Validation of a cost-effective alternative for a radiochromatography method to be used in a developing country.

F P Ekoume, H H Boersma, F Dong À Zok, S M Rubow

Abstract read
In one paragraph

Article in EJNMMI radiopharmacy and chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

F P EkoumeDepartment of Nuclear Medicine, Yaoundé General Hospital, P.O. Box 5408, Yaoundé, Cameroon.
H H BoersmaDepartment of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Hanzeplein 1, P.O. Box 30.001, 9700RB, Groningen, The Netherlands. h.h.boersma@umcg.nl.ORCID http://orcid.org/0000-0003-1892-9830
F Dong À ZokDepartment of Nuclear Medicine, Yaoundé General Hospital, P.O. Box 5408, Yaoundé, Cameroon.
S M RubowNuclear Medicine Division, Stellenbosch University, P.O. Box 241, 8000, Cape Town, South Africa.

Funding

IAEA Travel Grant
6 · The paper itself

Abstract

introductionThe radiochemical purity (RCP) of technetium-99m labelled radiopharmaceuticals (RP) is important to ensure optimal scintigraphic image quality. In low-income settings, it may not be possible to use compendial analytical methods or expensive equipment for radiochemical purity analysis. All radiochemical analysis methods should however be validated against compendial or otherwise proven methods. To ensure the efficacy of RP prepared at Yaoundé General Hospital (YGH) Cameroon, this study cross-validated a cost-effective routine chromatographic method using a simple survey meter technique. A GMP-compliant method used at the University Medical Center Groningen (UMCG), the Netherlands was used as the comparator.

methodsSestamibi, HMDP and DMSA kits currently used at YGH were reconstituted at UMCG with about 2000 MBq of freshly eluted sodium pertechnetate as described by the manufacturer, and spiked with eluate of the same generator to obtain a range of impurity concentrations. Samples of technetium-99m RP were spotted on 1 × 10 cm iTLC-SG strips and developed in appropriate mobile phases. Each strip was first scanned on the chromatogram-scanner used at the UMCG (standard method), and immediately thereafter the strip was cut in two pieces and radioactivity from each portion was counted with a small survey meter from YGH. The percentage RCP for each TLC strip was calculated using both counting methods. Internationally recommended validation parameters and acceptance criteria were used. Student's paired t-test or ANOVA were used with 'no significant difference' designated at a 95% confidence-interval (P ≥ 0.05). Linearity of the survey meter was determined for Tc-99m. Readings obtained with the survey meter were also plotted against the scanner results. RESULTS AND DISCUSSION: The proposed method proved to be accurate (CV of mean RCP < 2), precise (RSD < 2%), linear (slope close to 1, r

conclusionThe proposed method compared well with the standard method and is suitable as a reliable low cost method for limited resource settings.

Indexed as

Developing countriesQuality controlRadiochemical method

Identifiers

PMID32277373
PMCPMC7148399

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.