Evidence map›Paper›PMID 32275668›Full record

ArticlePloS one2020

Faster 3D saturation-recovery based myocardial T1 mapping using a reduced number of saturation points and denoising.

Giovanna Nordio, Aurelien Bustin, Freddy Odille, Torben Schneider, Markus Henningsson, Claudia Prieto, René M Botnar

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Giovanna NordioSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, England, United Kingdom.ORCID 0000-0002-7835-2992
Aurelien BustinSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, England, United Kingdom.ORCID 0000-0002-2845-8617
Freddy OdilleCIC-IT 1433, INSERM, Université de Lorraine and CHRU de Nancy, Nancy, France.
Torben SchneiderPhilips Healthcare, Guildford, England, United Kingdom.
Markus HenningssonSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, England, United Kingdom.
Claudia PrietoSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, England, United Kingdom.
René M BotnarSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, England, United Kingdom.

Funding

Department of HealthMedical Research Council MR/L009676/1Wellcome TrustWellcome Trust NS/A000049/1Wellcome Trust WT 203148/Z/16/Z
6 · The paper itself

Abstract

purposeTo accelerate the acquisition of free-breathing 3D saturation-recovery-based (SASHA) myocardial T1 mapping by acquiring fewer saturation points in combination with a post-processing 3D denoising technique to maintain high accuracy and precision.

methods3D SASHA T1 mapping acquires nine T1-weighted images along the saturation recovery curve, resulting in long acquisition times. In this work, we propose to accelerate conventional cardiac T1 mapping by reducing the number of saturation points. High T1 accuracy and low standard deviation (as a surrogate for precision) is maintained by applying a 3D denoising technique to the T1-weighted images prior to pixel-wise T1 fitting. The proposed approach was evaluated on a T1 phantom and 20 healthy subjects, by varying the number of T1-weighted images acquired between three and nine, both prospectively and retrospectively. Following the results from the healthy subjects, three patients with suspected cardiovascular disease were acquired using five T1-weighted images. T1 accuracy and precision was determined for all the acquisitions before and after denoising.

resultsIn the T1 phantom, no statistical difference was found in terms of accuracy and precision for the different number of T1-weighted images before or after denoising (P = 0.99 and P = 0.99 for accuracy, P = 0.64 and P = 0.42 for precision, respectively). In vivo, both prospectively and retrospectively, the precision improved considerably with the number of T1-weighted images employed before denoising (P<0.05) but was independent on the number of T1-weighted images after denoising.

conclusionWe demonstrate the feasibility of accelerating 3D SASHA T1 mapping by reducing the number of acquired T1-weighted images in combination with an efficient 3D denoising, without affecting accuracy and precision of T1 values.

Indexed as

Cardiovascular DiseasesHeartHumansImaging, Three-DimensionalMagnetic Resonance ImagingPhantoms, ImagingRetrospective Studies

Identifiers

PMID32275668
PMCPMC7147792

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.