Observational studyAnnals of cardiac anaesthesia
Comparison of continuous cardiac output monitoring derived from regional impedance cardiography with continuous thermodilution technique in cardiac surgical patients.
Observational study in Annals of cardiac anaesthesia. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 9 citations in OpenAlex.
- Bile Acid Pool Expansion and Hemodynamic Associations of the Secondary-to-Primary Bile Acid Ratio in Adult Fontan Circulation.Pediatric cardiology · 2026Article
- Comparison of cardiac index values between bioimpedance and pulse contour analysis in patients undergoing cardiac surgery under cardiopulmonary bypass.Indian journal of anaesthesia · 2026Article
- Non-Invasive Measurement of Hemodynamic Parameters via Whole-Body Impedance Cardiography Among Hospitalized Heart Failure Patients: An Effective Alternative to Invasive Right Heart Catheterization?Journal of cardiovascular development and disease · 2025Article
- Combination of echocardiography with systemic hemodynamic parameters for early risk stratification of hemodynamically significant patent ductus arteriosus in preterm infants.Frontiers in pediatrics · 2025Article
- Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm.Sensors (Basel, Switzerland) · 2023Article
- Noninvasive Hemodynamic Monitoring in Advanced Heart Failure Patients: New Approach for Target Treatments.Biomedicines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Cardiac output (CO) assessment is a corner stone in advanced haemodynamic management, especially in critical ill patients. The present study was conducted to validate cardiac index and cardiac output by NICaS™ with the thermodilution technique using pulmonary artery catheter in post-operative cardiac surgical patients. Materials and Methods: This was a prospective observational clinical study conducted at a tertiary care hospital. 23 adult patients in the age range of 18-65 years who had undergone for elective coronary artery bypass grafting were included in the study. Results: Spearman's correlation coefficient of cardiac index between continuous Thermodilution (cTD) and Non-Invasive Cardiac System (NICaS™) showed a good correlation (r = 0.765, 95% confidence interval 0.70 to 0.82, P < 0.0001). There was a good correlation between cTD and NICaS™ for cardiac output (r = 0.759, 95% confidence interval 0.69 to 0.81, P < 0.0001), Bland-Altman plot for cardiac index between cTD and NICaS™ showed a mean bias of -0.66 ± 0.6919 with limits of agreement being -2.02 to 0.6936. Bland-Altman plot for cardiac output between cTD and NICaS™ showed a mean bias of -1.0386 ± 1.17 with limits of agreement being -3.34 to + 1.26. Percentage error for cardiac index and cardiac output were 64.78% and 64% respectively. Polar plot analysis showed an angular bias of 6.32° with radial limits of agreement being -8.114° to 20.75° for cardiac index and angular bias of 5.6682° with radial limits of agreement being -9.1422° to 20.4784° for cardiac output. Conclusion: NICaS™ demonstrated a good trending ability for both CI and CO. However, NICaS™ derived parameters are not interchangeable with the values derived from continuous thermodilution technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.