Evidence map›Paper›PMID 32272964›Full record

ArticleJournal of neuroengineering and rehabilitation2020

Design of a lightweight passive orthosis for tremor suppression.

Nicolas Philip Fromme, Martin Camenzind, Robert Riener, René M Rossi

Open access · goldAbstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.9field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 41 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Essential Tremor Suppression with a Novel Anti-Tremor Orthosis: A Randomized Crossover Trial.Movement disorders : official journal of the Movement Disorder Society · 2025
    Trial
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Nicolas Philip FrommeLaboratory for Biomimetic Membranes and Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014, St. Gallen, Switzerland.
Martin CamenzindLaboratory for Biomimetic Membranes and Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014, St. Gallen, Switzerland.
Robert RienerSensory-Motor Systems Lab, Department of Health Sciences and Technology, Institute of Robotics and Intelligent Systems, ETH Zurich, Tannenstrasse 1, TAN E 5, 8092, Zurich, Switzerland.
René M RossiLaboratory for Biomimetic Membranes and Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014, St. Gallen, Switzerland. Rene.Rossi@empa.ch.
Swiss Federal Laboratories for Materials Science and Technology · CHETH Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTremor is the most common movement disorder with the highest prevalence in the upper limbs. The mechanical suppression of involuntary movements is an alternative and additional treatment to medication or surgery. Here we present a new, soft, lightweight, task asjustable and passive orthosis for tremor suppression.

methodsA new concept of a manual, textile-based, passive orthosis was designed with an integrated, task adjustable, air-filled structure, which can easily be inflated or deflated on-demand for a certain daily activity. The air-filled structure is placed on the dorsal side of the wrist and gets bent and compressed by movements when inflated. In a constant volume air-filled structure, air pressure increases while it is inflating, creating a counterforce to the compression caused by bending. We characterised the air-filled structure stiffness by measuring the reaction torque as a function of the angle of deflection on a test bench. Furthermore, we evaluated the efficacy of the developed passive soft orthosis by analysing the suppression of involuntary movements in the wrist of a tremor-affected patient during different activities of daily living (i.e. by calculating the power spectral densities of acceleration).

resultsBy putting special emphasis on the comfort and wearability of the orthosis, we achieved a lightweight design (33 g). The measurements of the angular deflection and resulting reaction torques show non-linear, hysteretic, behaviour, as well as linear behaviour with a coefficient of determination (R

conclusionThe orthosis we developed is a lightweight and unobtrusive assistive technology, which suppresses involuntary movements and shows high wearability properties, with the potential to be comfortable. This air-structure technology could also be applied to other movement disorders, like spasticity, or even be integrated into future exoskeletons and exosuits for the implementation of variable stiffness in the systems.

Indexed as

Orthotic DevicesHumansMaleProsthesis DesignTremorWrist JointComfortLaser weldingOrthosisSoftSuppressionTextile integratedTremorUpper limbVariable stiffnessWearable

Identifiers

PMID32272964
PMCPMC7144059
OpenAlexW3015809696

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.