Evidence map›Paper›PMID 32271836›Full record

ArticlePloS one2020

Deep learning-based smart speaker to confirm surgical sites for cataract surgeries: A pilot study.

Tae Keun Yoo, Ein Oh, Hong Kyu Kim, Ik Hee Ryu, In Sik Lee, Jung Sub Kim, Jin Kuk Kim

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.8field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Influence of Audio Speech Rate and Source Text Difficulty on Health Information Comprehension and Retention.Proceedings of the ... Annual Hawaii International Conference on System Sciences. Annual Hawaii International Conference on System Sciences · 2024
    Article
  7. Review
  8. Article
  9. Review
  10. Review
  11. Article
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Tae Keun YooDepartment of Ophthalmology, Aerospace Medical Center, Republic of Korea Air Force, Cheongju, South Korea.ORCID 0000-0003-0890-8614
Ein OhDepartment of Anesthesiology and Pain Medicine, Seoul Women's Hospital, Bucheon, South Korea.
Hong Kyu KimDepartment of Ophthalmology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, South Korea.ORCID 0000-0002-0865-109X
Ik Hee RyuB&VIIt Eye Center, Seoul, South Korea.
In Sik LeeB&VIIt Eye Center, Seoul, South Korea.
Jung Sub KimB&VIIt Eye Center, Seoul, South Korea.
Jin Kuk KimB&VIIt Eye Center, Seoul, South Korea.
Nune Eye Hospital · KRDankook University Hospital · KRKorea Air Force Academy · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wrong-site surgeries can occur due to the absence of an appropriate surgical time-out. However, during a time-out, surgical participants are unable to review the patient's charts due to their aseptic hands. To improve the conditions in surgical time-outs, we introduce a deep learning-based smart speaker to confirm the surgical information prior to cataract surgeries. This pilot study utilized the publicly available audio vocabulary dataset and recorded audio data published by the authors. The audio clips of the target words, such as left, right, cataract, phacoemulsification, and intraocular lens, were selected to determine and confirm surgical information in the time-out speech. A deep convolutional neural network model was trained and implemented in the smart speaker that was developed using a mini development board and commercial speakerphone. To validate our model in the consecutive speeches during time-outs, we generated 200 time-out speeches for cataract surgeries by randomly selecting the surgical statuses of the surgical participants. After the training process, the deep learning model achieved an accuracy of 96.3% for the validation dataset of short-word audio clips. Our deep learning-based smart speaker achieved an accuracy of 93.5% for the 200 time-out speeches. The surgical and procedural accuracy was 100%. Additionally, on validating the deep learning model by using web-generated time-out speeches and video clips for general surgery, the model exhibited a robust and good performance. In this pilot study, the proposed deep learning-based smart speaker was able to successfully confirm the surgical information during the time-out speech. Future studies should focus on collecting real-world time-out data and automatically connecting the device to electronic health records. Adopting smart speaker-assisted time-out phases will improve the patients' safety during cataract surgeries, particularly in relation to wrong-site surgeries.

Indexed as

Cataract ExtractionDeep LearningCataractCell PhoneElectronic Health RecordsHumansMedical ErrorsPilot ProjectsSpeech

Identifiers

PMID32271836
PMCPMC7144990
OpenAlexW3000280400

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.