Evidence map›Paper›PMID 32260289›Full record

ArticleJournal of clinical medicine2020

Direct Rapid Left Ventricular Wire Pacing during Balloon Aortic Valvuloplasty.

Pawel Kleczynski, Artur Dziewierz, Sylwia Socha, Tomasz Rakowski, Marzena Daniec, Barbara Zawislak, Saleh Arif, Joanna Wojtasik-Bakalarz, Dariusz Dudek, Lukasz Rzeszutko

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.9field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Balloon aortic valvuloplasty for severe aortic stenosis may reduce mitral regurgitation in mid-term follow-up.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2022
    Article
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Pawel KleczynskiDepartment of Interventional Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Pradnicka 80 Street, 31-202 Krakow, Poland.
Artur Dziewierz2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Sylwia SochaDepartment of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Tomasz Rakowski2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Marzena DaniecDepartment of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Barbara Zawislak2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Saleh ArifDepartment of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Joanna Wojtasik-BakalarzDepartment of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Dariusz Dudek2nd Department of Cardiology, Jagiellonian University Medical College, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Lukasz RzeszutkoDepartment of Cardiology and Cardiovascular Interventions, University Hospital, Jakubowskiego 2 Street 30-688 Krakow, Poland.
Jagiellonian University · PLUniversity School of Physical Education in Kraków · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRapid ventricular pacing is mandatory for optimal balloon positioning during aortic valvuloplasty (BAV) in patients with severe aortic stenosis. We aimed to assess the safety and efficacy of direct left ventricular (LV) guidewire pacing in comparison with regular pacing induced by temporary pacemaker (PM) placement in the right ventricle.

methodsDirect rapid LV pacing was provided with a 0.035″ guidewire. Baseline clinical characteristics, echocardiographic and procedural data, as well as complication rates, were compared between the two groups.

resultsA total of 202 patients undergoing BAV were enrolled (49.5% with direct LV guidewire pacing). The pacing success rate was 100%. In the direct LV guidewire pacing group, we found a lower radiation dose, shorter fluoroscopy and overall procedural time (0.16 vs. 0.28 Gy,

conclusionsDirect rapid LV guidewire pacing is a simple, safe and effective option for BAV with a reduced complication rate compared to a temporary PM placed in the right ventricle.

Indexed as

aortic valve stenosisballoon aortic valvuloplastypacingwire

Identifiers

PMID32260289
PMCPMC7230545
OpenAlexW3014724466

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.