Evidence map›Paper›PMID 32257033›Full record

ArticleIndian journal of orthopaedics2020

Blood Management in Revision Total Hip Arthroplasty for Metal-on-Metal Devices: The Efficiency of an Intraoperative Cell Salvage System.

Werner Maurer-Ertl, Andreas Fellner, Patrick Reinbacher, Michael Maier, Andreas Leithner, Joerg Friesenbichler

Abstract read
In one paragraph

Article in Indian journal of orthopaedics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Werner Maurer-Ertl1Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
Andreas Fellner2Department of Anaesthesiology, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
Patrick Reinbacher1Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
Michael Maier1Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
Andreas Leithner1Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
Joerg Friesenbichler1Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this series was to investigate the efficiency of an intraoperative cell salvage system (ICS) removing metal ions during revision of metal-on-metal (MoM) devices to proof the possibility of re-transfusion of the collected blood. MATERIALS AND

methodsBetween 2014 and 2018, five consecutive patients underwent revision surgery of their MoM total hip arthroplasty due to wear of the polyethylene-metal sandwich inlay or local massive metallosis with aseptic loosing of the cup. Aspiration of joint fluid of all hip prostheses was done and blood was taken to measure the metal ion concentrations, preoperatively. Perioperatively, blood was collected using an ICS before and after filtration and analyzed for Co and Cr concentrations. At that time, there was no re-transfusion of the collected and filtrated blood due to unknown metal ion concentrations.

resultsThe mean preoperative serum Co and Cr concentrations in the blood were 31.28 μg/L (range 0.22-77.47) and 17.33 μg/L (range 0.59-51.31), whereas the mean local concentrations in the aspiration fluid were 728-fold and 822-fold higher. The Co and Cr concentrations measured in the collected blood before filtration were 70.61 μg/L (range 9.40-173.00) and 337.21 μg/L (range 8.76-1383.0) and decreased markedly to average concentrations of 15.49 μg/L and 41.88 μg/L, respectively. These differences were statistically not significant (Co:

conclusionThe current series showed that in case of revision of MoM hip devices, metal ions are still contained in the collected blood following filtration using a modern high-level ICS. Therefore, we would only recommend blood re-transfusion in case of low preoperative Co and Cr concentrations and sufficient renal function to warrant patients' safety.

Indexed as

ArthroplastyBlood salvageChromiumCobaltHip

Identifiers

PMID32257033
PMCPMC7096336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.