ArticleJournal of arrhythmia2020
Atrial signal amplitude predicts atrial high-rate episodes in implantable cardioverter defibrillator patients: Insights from a large database of remote monitoring transmissions.
Article in Journal of arrhythmia, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 8 citations in OpenAlex.
- Predictors for Device-Detected Subclinical Atrial Fibrillation: An Up-to-Date Narrative Review.Journal of clinical medicine · 2026Review
- Article
- How to get the optimal defibrillation lead parameters using myocardial perfusion scintigraphy in patients with coronary artery disease.The international journal of cardiovascular imaging · 2021Article
- Atrial signal amplitude predicts atrial high-rate episodes in implantable cardioverter defibrillator patients: Insights from a large database of remote monitoring transmissions.Journal of arrhythmia · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
25 authors at 18 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundParameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D).
methodsIn the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE).
resultsIn a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV,
conclusionsAlthough lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.